FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con
Error! No text of specified style in document.
Event
Number
(dec/hex)
Event
Name
Logged?
Predictive
Maintenance
Implication
Suspected
Components
Mf
g Fail?
Description
460/0x1cc
TWSI Write Failure
Y
Controller,
battery, power-
supply,
midplane
Y
The two-wire serial bus module retried the write and
was either not able to get a response from the
device, the transaction failed, or the bus failed. In
the case of a bus failure, the bus was good at the
time the read request was made. Now it has failed.
461/0x1cd
TWSI transmit Failure
Y
Controller,
battery, power
supply,
midplane
Y
The two-wire serial bus module retried the transmit
and was either not able to get a response from the
device, the transaction failed, or the bus failed. In
the case of a bus failure, the bus was good at the
time the read request was made. Now it has failed.
462/0x1ce
EEPROM now present
Y
N
The eeprom was marked as not present because of
"no hardware" status from the TWSI module. Upon
further attempts to communicate, the device is now
responding.
463/0x1cf
EEPROM new status
Y
N
The status (GOOD, NOT_PRESENT, FAILED,
CRITICAL) has changed.
464/0x1d0
EEPROM Selftest Passed
Y
Midplane
N
The eeprom selftest was able to verify that the
midplane eeproms are mirrored.
465/0x1d1
EEPROM Selftest Failed
Y
Midplane
Y
The selftest of the mirrored eeproms detected the
data was not identical between the pair. An attempt
to fix this inconsistancy failed.
466/0x1d2
EEPROM Read Failed
Y
Midplane
Y
The firmware was not able to read correctly from
either of the mirrored midplane eeproms.
467/0x1d3
EEPROM Write Failed
Y
Midplane
Y
The firmware was not able to read correctly from
either of the mirrored midplane eeproms.
468/0x1d4
EEPROM not mirrored
Y
Midplane
Y
The firmware was not able to read or write correctly
from one of the mirrored midplane eeproms. The
system is no longer fully redundant.
469/0x1d5
EEPROM can not get wwn
Y
Midplane
Y
During a request for a new lun WWN, the firmware
was not able to read from either of the midplane
eeproms. This is can be due to a variety of TWSI
failures or the eeprom failing. The eeprom can only
create 2,000 trillion (2 quadrillion) LUN’s. If this
limit has been exceeded, the midplane must be
replaced.
470/0x1d6
Firmware clone complete
Y
N.A.
N
Cloning of firmware to the other controller has
completed.
471/0x1d7
Firmware clone failed.
Y
Controller or
midplane
N.A.
N
Cloning of firmware to the other controller has
failed.
472/0x1d8
VSC7130_INT_DISABLE_EH Y
VSC7130
Signal Detect /
Port Bypass
Control chip
Y
We’ve exceeded the maximum number of retries in
attempting to clear a VSC7130 signal detect
interrupt. The interrupt is being disabled to allow
other TWS devices sharing the interrupt line to be
able to generate interrupts. When this condition
exists, the controller will not be able to respond to
JBOD cable insertion and removal instantaneously,
instead it will take up to five seconds to recognize
the state change. This condition generally indicates
bad FC conditions or a problem with the 7130.
473/0x1d9
LCC_DEVICE_STATE_INV
ALID_EH
Y
LCC/ESD
N
Happens when a JEM is no longer allowed to send
requests to an LCC its retries are zeroed. The
current outstanding I/O may complete but no
additional I/O will be started.
474/0x1da
LCC_EVENT_EH
Y
LCC/ESD
N
Status of elements as well as information on the
LCC.
475/0x1db
LCC_DATA_LENGTH_ERR
OR_EH
Y
LCC/ESD
N
The amount of data sent by the LCC was not what
was expected or calculated.
476/0x1dc
LCC_NOT_SUPPORTED_ER
ROR_EH
Y
LCC/ESD
N
Data that was received from the LCC was not
supported. e.g. LCC F/W not supported or a NEW
element type is not supported by the array F/W.
477/0x1dd
LCC_RETRIES_EXCEEDED
_EH
Y
LCC/ESD
N
The retries for an I/O have been exceeded.
478/0x1de
LCC_ELEMENT_EXCEEDE
D_MAX_EH
Y
LCC/ESD
N
The number of elements ,for a specific element type,
exceeded the maximum allowed. (e.g. Disk element
type reports 60 drives in a single JBOD)
479/0x1df
LCC_STORAGE_EXCEEDE
D_EH
Y
LCC/ESD
N
Exceeded element or status storage space.
480/0x1e0
LCC_JEM_DELETE_DONE_
Y
LCC/ESD
N
Topology Manager requested a delete of a JEM.