Event
Number
(dec/hex)
Event
Name
Logged?
Predictive
Maintenance
Implication
Suspected
Components
Mf
g Fail?
Description
provided by
drive vendor
CHECK_CONDITION, MEDIA_ERROR. The
PDD’s retries are exhausted. The PDD may or may
not have attempted a REASSIGN BLOCKS
command.
24/0x18
Disk Drive Hardware Error
Y
See information
provided by
drive vendor
Disk Drive
N
The disk drive returned a status of
CHECK_CONDITION, HARDWARE_ERROR.
The PDD’s retries are exhausted or the the I/O is not
retryable.
25/0x19
Disk Drive Reset By Related
Hot Plug
N
N.A.
None
N
A device sharing the same backend bus as this drive
was either inserted or removed causing a bus reset.
The ID returned status of HOT_RESET_ID for this
I/O. The PDD could not retry this I/O either
because it is not retryable, or its retries were
exhausted.
26/0x1a
Disk Drive Reset Itself
Y
Ingore if
accompanied by
hot plug.
Disk Drive
N
The disk drive returned a status of
CHECK_CONDITION, UNIT_ATTENTION,
PWR_ON_RESET. The PDD could not retry this
I/O. If there wasn’t already a reconfiguration in
progress when the PDD got the callback for this I/O,
the PDD used the JCB for this I/O to reconfigure the
drive; the UNIT ATTENTION condition has
already been cleared. Recommend that the client
retry the I/O.
27/0x1b
Disk Drive Reset by Pass
Through
Y
Ignore
None
N
A passThruReset occurred. The PDD could not
retry this I/O.
28/0x1c
Disk IO Failed Due To Drive
Removal
N
N.A.
None
N
Subsequent to a hot removal, the PDD’s destroy
method was invoked. I/Os in the PDD’s waiting
queue are flushed with this status. Active I/Os
which complete with good status, after the destroy
method is invoked, but which executed during a
device configuration, will also be returned with this
status. (Active I/Os which complete with good
status status and not concurrent with device
configuration will be returned with good status.)
29/0x1d
Disk Drive Failed Initialization
Y
N.A.
None
Y
A disk drive failed the reconfiguration attempt
(TUR, inquiry, mode sense, mode select, read
capacity). The PDD attempted a device
reconfiguration after the device was reset during the
normal course of operation (i.e. not during a hotplug
of this drive, but possibly during a hotplug of
another drive). If the device reconfiguration fails,
the PDD flushes all non-passthru I/Os from its
waiting queue with this status. The I/O whose JCB
was used for the config is also returned with this
status. If there was active I/Os concurrent with the
config, it is also returned with this status.
30/0x1e
Disk I/O Failed Due To
Related Hot Plug
Y
Ignore.
None
N
The I/O executed concurrently with a device
reconfiguration. The state of the drive was
unknown (danger of write cache being enabled.)
The I/O was not retryable or the PDD’s retries are
exhausted. The I/O should be retried by the client.
31/0x1f
Unexpected Disk Drive Error
Y
Single
Occurrance
Unless Excluded
For Drive Type
Disk Drive
N
The drive returned CHECK CONDITION status
with meaningless sense data, or sense data not
otherwise handled by the PDD’s error recovery
algorithms. The PDD’s retries are exhausted or the
I/O is not retryable.
32/0x20
Invalid SLRC transition
N
N.A.
None
N
An attempt was made to change the SLRC mode
parameter from a value of AutoRAID to RAID1
while LUNs were configured in the subsystem. This
transition cannot be made unless no LUNs are
configured.
33/0x21
Disk Drive Miscompare on
Write And Verify
Y Single
Occurrance
Disk Drive,
Controller, Disk
Interface
N
The disk drive returned a MISCOMPARE error
status. The PDD’s retries are exhausted or the I/O is
not retryable.
34/0x22
Disk Drive State Conflict
Y
Ignore
None
N
The PDM was in the wrong state for read, write or
pass thru. down, missing or initialization failed.
missing.
35/0x23
Disk Drive Data Out Of Sync
After Access
Y
Ingore - See
accomapnying
errors
None
N
Data being read or written on a device through the
PDM was out of sync after the access was complete.
36/0x24
Illegal Drive State For Down
N
N.A.
None
N
A state conflict was detected in an attempt to down