HP StorageWorks 7100 - Virtual Array Скачать руководство пользователя страница 25

Event 

Number 

(dec/hex) 

Event 
Name 

Logged? 

Predictive 

Maintenance 

Implication 

Suspected 
Components 

Mf

g Fail? 

Description 

520/0x208 

The over temperature error bit 
is set 

 

Power Supply 

The over current error bit is set in the power supply 
expander  

521/0x209 

The under voltage error bit is 
set 

 

Power Supply 

The under voltage error bit is set in the power 
supply expander  

522/0x20a 

Dram text area cksum error 

 

Controller 

The DRAM Text area checksum does not match the 
checksum calculated during initialization. A bgm 
timer polls to check the CKSUM once every hour.  

523/0x20b 

Software address warning 

 

Controller 

This warning indicates that there is switch conflict 
in the JBOD enclosures. Two or more enclosure 
switches are set to the same address.   

524/0x20c 

LCC switch address warning 

 

Controller 

This warning indicates that there is an LCC switch 
mismatch within a JBOD enclosures.   

525/0x20d 

Power supply not present 

 

Power Supply 

This warning indicates that the power supply is not 
present  

526/0x20e 

Map Disk Event 

 

Controller 

This error code indicates that the Topology Manager 
MAP DISK code had an event that it has logged. 
The defined events are REDUNDANT MAP 
DISKS, MAP_DISK_REDUNDANCY_LOSS, and 
NO_MAP_DISKS. 

527/0x20f 

Battery NVRAM backup 
command 

Y  NVRAM 

battery charger 

The command sent to enable or disable the batteries 
from backing up the NVRAM has failed. 

528/0x210 

Unsupported host port behavior 
table revision 

Ignore 

None 

The host port behavior table that was read from 
chassis NV memory contains an unsupported 
revision value.  The RAM-based table will be 
initialized as empty. 

529/0x211 

Host Port Behavior table was 
initialized as empty 

 

None 

The host port behavior table was initialized as 
empty due to a failure to read the contents from 
chassis NV storage. 

530/0x212 

Firmware download failed 

Ignore.  These 

should be 

detected by the 

download utility. 

none 

A firmware download operation failed.  The details 
of the failure are included in the event unique 
section of the event and other events logged in 
conjunction with this one. 

531/0x213 

AutoFormat Event Occured 

Ignore unless no 

Operator activity 

Disk Drive, 
Back End FC 
Link 

An AutoFormat event was logged, this is caused 
either by a backend format of an internal drive 
beginning or completing.  Look as the associated 
data for drive and status. 

532/0x214 

Power supply is not connected 
to an AC source 

 

Power Supply 

This warning indicates that the power supply is not 
connected to an AC source. 

533/0x215 

Some non-critical midplane 
eeprom data was not restored. 

Y  Midplane 

EEPROM 

This warning indicates that some non-critical 
eeprom data was not restored during the automatic 
restore process.  The user should be able to replace 
this data by hand.  (Licenses, mode parms, Host port 
behavior, etc. 

534/0x216 

Automatic midplane repair 
failed. 

Y  Midplane 

EEPROM 

This warning indicates the automatic midplane 
eeprom repair process has failed because of bad 
NVSRAM data.  The repair can not be done. 

535/0x217 

Temp sensor exceeded warning 
temperature. 

Y  Controller 

Temp Sensor 

The temperature sensor has exceeded the 
recommended temperature for asserting an over-
temp warning. 

536/0x218 

Temp sensor exceeded 
shutdown temperature. 

Y  Controller 

Temp Sensor 

The temperature sensor has exceeded the 
recommended temperature for issuing a controller 
shutdown. 

537/0x219 

Temp sensor is now in range. 

 

Controller 
Temp Sensor 

The temperature sensor had exceeded the 
recommended temperature for asserting a warning.  
The temperature has now come back down within 
range.  There is 3 degrees C of hysteresis. 

538/0x21a 

Disk interface online. 

Ignore 

Disk interface 

A disk interface has come online and is functional.  
This occurs normally during reset or reconfiguration 
(hotplug). 

539/0x21b 

Disk interface device 
discovered. 

Ignore 

Disk interface 

A device has been discovered on a disk interface 
during reset or reconfiguration (hotplug).  This is 
normal. 

540/0x21c 

Disk interface device logout 

Ignore 

Disk Interface 

The login to a device on a disk interface has been 
closed.  This occurs normally during reconfiguration 
(hotplug). 

541/0x21d 

Disk interface error count has 
incremented 

Y Ignore, 

unless 

occurring 

frequently 

Disk interface 

The count of link-level errors on a disk interface has 
incremented.  This can occur under normal 
circumstances (especially with disk hotplug), so it 
does not indicate a problem unless it occurs 
frequently. 

Содержание StorageWorks 7100 - Virtual Array

Страница 1: ... array changes to the configuration of the array performance data port error statistics Table 1 lists all event codes that can appear in the controller log event pages The table also includes events that are not logged but can still generate SCSI sense data Appropriate corrective action is included for all events that require it Many events are informational and require no action on the part of th...

Страница 2: ...are error during a selftest operation 13 0xd Commands Cleared Unit Attention N N A None N Another originator sent commands to the array that resulted in commands being cleared for the current originator 14 0x0e Mode Parameters Changed Unit Attention N N A None N Another initiator sent commands to the array that resulted in shared mode parameters being changed for the current initiator 15 0x0f Unco...

Страница 3: ...A None Y A disk drive failed the reconfiguration attempt TUR inquiry mode sense mode select read capacity The PDD attempted a device reconfiguration after the device was reset during the normal course of operation i e not during a hotplug of this drive but possibly during a hotplug of another drive If the device reconfiguration fails the PDD flushes all non passthru I Os from its waiting queue wit...

Страница 4: ... 0x2c Invalid RG ID N N A None N A command that specifies an Redundancy Group ID specified one that is invalid for the current subsystem configuration 45 0x2d Shutdown Failed N N A None N CFM could not shutdown the subsystem because no volume set members were present all members missing 46 0x2e Not Enough Space Y Ignore See accompanying errors None Y A write command had to move data in order to fi...

Страница 5: ...See accompanying errors None N R1 detected that the devices necessary for a write were not available for access before the access was attempted This can apply to an initial attempt to write or to a retry 59 0x3b Disk Interface Error Y N A None Y An error occurred on a disk interface command 60 0x3c Unsupported feature N Ignore Device Management error None Y An attempt was made to install a license...

Страница 6: ...uld retry the operation 78 0x4e Silent Disk Drive Error Recovery N N A None N On a previous attempt s the drive failed the I O Usually due to hot plug The PDD retried the I O and the drive returned good status We do not log a recovered error because the original error was not logged We report GOOD status to the host 79 0x4f Check Condition From Disk Drive With No Sense Y Single Occurrence Disk Dri...

Страница 7: ...troller does not have sufficient information to determine the extent of the damage 94 0x5e Volume Set Missing During Recovery Y ignore operator error None Y The volume set referenced in a recover command is not present in the subsystem If a NULL volume set was referenced then this error indicates that no members of any volume set were present This error can also result from imcompatible stamp vers...

Страница 8: ...ermission to access LUN None Y The Host attempted to perform an operation on LUN without having an appropriate access permission 112 0x70 Host can not be authenticated to access LUN Security map Y Ignore Provide correct password None N The Host failed the authentication for access to LUN Security map because the password that it presented is incorrect 113 0x71 Limit to Maximum number of Principals...

Страница 9: ...pected error 131 0x83 Disk Interface Command Failed Y N A None N A command to a backend device failed due to an error that does not include sense data from the device 132 0x84 Host is not authorized to access LUN Y Ignore Host doesn t have permission to access LUN None Y LUN Security Authoriztion failed Host attempted to perform an operation on a LUN without having an appropriate access permission...

Страница 10: ...leted successfully This message follows the message 267 0x10b Insufficient Space To Start Rebuild Y Ignore See accompanying errors None N here is insufficient disk space for rebuild to execute This message followsthe message and may follow the REBUILD message 268 0x10c Rebuild Failed Y Ignore See accompanying errors None N ebuild has failed to complete due to multiple disk failures or a controller...

Страница 11: ...ification succeeds 279 0x117 Disk Set Attached Y Ignore Operator activity None N This error code indicates the system state change consisting of attachment to a new volume set has occurred This occurs after every format subsystem and whenever a power on or reset occurs while the controller is not attached to a volume set In some cases the currently attached volume set may be empty 280 0x118 Reset ...

Страница 12: ...ta may then be successfully migrated 290 0x122 Warm Boot IO Expander Fault Y Ignore if recovered by power cycle Controller Y This error code indicates that the IO Expander containing the warm boot bit did not power on in the correct default condition or that attempts to set the warm boot bit in the IO Expander failed 291 0x123 Disk Set Detached Y Ignore Operator Host activity None N This is a syst...

Страница 13: ...r This error is logged only once per power on 303 0x12f No Interrupts From Other Controller Y Single Occurrance Controller Backplane N he other controller interrupt seems to be broken The timer interrupt fired multiple times with new communication messages but no other controller interrupts were present This error is logged only once per power on 304 0x130 Disk Interface Disconnect Y Ignore Disk c...

Страница 14: ...an expected 319 0x13f Disk Interface Overrun Event Y Single Occurrance not with other entries Disk controller disk interface N An attached disk sent received more data than expected 320 0x140 Disk Interface Timeout Event Y 2 occurrances per hot plug insert or removal Disk controller disk interface N A command to an attached disk did not complete within the allotted time 321 0x141 Controller ECC Mi...

Страница 15: ...6 0x150 Disk Interface State Event Y Single Occurrance not with other entries Controller disk disk interface N The disk interface controller and or software state information was incorrect for observed interface activity 337 0x151 Uncorrectable ECC Error During Initialization Y 1 in 6 months if no operator activity SIMM Controller N This error code indicates that the system experienced a unrecover...

Страница 16: ...50 0x15e RAM Version Mismatch Y N A None N The upload routine was unable to upload part of the disk NVRAM image because the current firmware does not support that use of RAM Most likely an older version of firmware is trying to upload a disk image posted by some other firmware version 351 0x15f Disk Format Version Mismatch Y N A None N The NVRAM format of the disks does not match the format used b...

Страница 17: ... This error code indicates that some non fatal error appeared in the shared memory error queue The two words of this queue entry will be placed in the log entry extended info area 363 0x16b Shared memory controller error Y Ignore if recovered by reset or power cycle Controller N This error code indicates that some fatal error appeared in the shared memory controller error queue The two words of th...

Страница 18: ...376 0x178 Frontend Fibre Channel Event Y Ignore None N This error code indicates that the Front End Fibre Channel port had an event that it has logged Specific information about the event is placed in the extended info area of the log 377 0x179 Frontend Services Event Y Ignore None N This error code indicates that a Front End Services FES event has occurred and has been logged Specific information...

Страница 19: ...en inserted into the enclosure 388 0x184 Internal drive removed Y Disk internal to the controller enclosure N An internal disk has been removed from the enclosure 389 0x185 Internal drive requesting port bypass Y Disk internal to the controller enclosure N An internal disk is requested that its FC port be bypassed 390 0x186 Internal drive has stopped requesting port bypass Y Disk internal to the c...

Страница 20: ...ler will be failed 419 0x1a3 VSC055 Interrupt Clear Failed Y VSC055 IO Expander Chip Y An attempt to clear an interrupt on the VSC055 indicated in the event extended information has failed The controller will be failed 420 0x1a4 Power supply was inserted Y Power Supply N The power supply has been inserted into the enclosure 421 0x1a5 Power supply status is GOOD Y Power Supply N The power supply ha...

Страница 21: ... charge is equal or higher than a specified threshold value 448 0x1c0 NVRAM battery status is UNKNOWN Y NVRAM battery N The status of the NVRAM battery is unknown This may be due to the firmware not being able to communicate with the battery 449 0x1c1 TWSI bus has been requested by another module Y Ignore unless occurring frequently Controller battery power supply N The battery management firmware...

Страница 22: ...wn Y Midplane Y During a request for a new lun WWN the firmware was not able to read from either of the midplane eeproms This is can be due to a variety of TWSI failures or the eeprom failing The eeprom can only create 2 000 trillion 2 quadrillion LUN s If this limit has been exceeded the midplane must be replaced 470 0x1d6 Firmware clone complete Y N A N Cloning of firmware to the other controlle...

Страница 23: ...tected an internal error 489 0x1e9 abterm reset Y controller N This event code indicates that the controller reset due to an abnormal termination in the firmware 490 0x1ea front panel reset Y controller N This event code indicates that the controller reset due to a request through the front panel 491 0x1eb host reset Y controller N This event code indicates that the controller reset due to a reque...

Страница 24: ...ta on the two eeproms at a given location was different This problem is usually fixed if the firmware can write to the eeproms 510 0x1fe FC Signal Detect Interrupt Y VSC7130 PBC Dual Repeater Chip N An interrupt on one of the VSC7130 port bypass control signal detect chips has occurred See the extended information for details 511 0x1ff Dual controller clock sync error Y controller N An interrupt f...

Страница 25: ...Y Ignore unless no Operator activity Disk Drive Back End FC Link N An AutoFormat event was logged this is caused either by a backend format of an internal drive beginning or completing Look as the associated data for drive and status 532 0x214 Power supply is not connected to an AC source Y Power Supply Y This warning indicates that the power supply is not connected to an AC source 533 0x215 Some ...

Страница 26: ...out Y Ignore Lab only none N The cross controller lock module failed to grant the decoder s lock in exclusive mode within the allowed period after an obtain request was deferred This may indicate a deadlock in the system or that the system is too busy 552 0x228 Decoder lock request was deferred Y Ignore Lab only none N The cross controller lock module deferred a request to obtain the decoder s loc...

Страница 27: ... mode parameters region contains a revision that is older than the revision expected by current firmware As a result some mode parameters were set to their default values since there was no saved value present in the EEPROM 577 0x241 Start multi disk loss scan Y Ignore should be other prior failure events controller N A backend scan was started to detect a multiple disk loss condition because of a...