FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con
 

Error! No text of specified style in document. 

Table 1. Controller Log Event Code Descriptions 

Event 

Number 

(dec/hex) 

Event 
Name 

Logged? 

Predictive 

Maintenance 

Implication 

Suspected 
Components 

Mf

g Fail? 

Description 

0/0x0 

No Sense 

N.A. 

None 

No sense data is available. 

1/0x01 

Undefined 

N.A. 

None 

Undefined event code. 

2/0x02 

Unsupported LUN Capacity 

N.A. 

None 

An attempt was made to create a LUN with an 
unsupported capacity.  The capacity was either zero 
or was greater than the maximum LUN capacity 
supported by the subsystem. 

3/0x03 

Parameter List Length Error 

N.A. 

None 

The length of the parameter list was incorrect for the 
command and it’s parameters. 

4/0x04 

Invalid Field In Parameter List 

N.A. 

None 

One or more of the fields in the parameter list 
contained an invalid value. 

5/0x05 

No Physical Device Present 

N.A. 

None 

A command attempted to access a device (disk or 
enclosure controller) that is not currently present in 
the subsystem. 

6/0x06 

Invalid Opcode 

N.A. 

None 

The opcode in the command that was received is not 
supported by the subsystem.  This error could be 
due to the LUN Security configuration. 

7/0x07 

Invalid Bit In CDB 

N.A. 

None 

One or more fields in the CDB contained an illegal 
or unsupported value. 

8/0x08 

Logical Block Address Out Of 
Range 

N.A. 

None 

The LBA specified in the command was out of 
range for the LUN that it was sent to. 

9/0x09 

Not Ready 

N.A. 

None 

The array is not ready to process the command that 
was received.  Furthermore, the array will not 
become ready until an initializing command is 
received and successfully processed. 

10/0x0a 

Undefined 

N.A. 

None 

Undefined event code. 

11/0x0b 

Power On Unit Attention 

N.A. 

None 

The array just completed a reset operation. 

12/0x0c 

Hardware Error Unit Attention 

N.A. 

None 

The most recent reset operation detected a hardware 
error during a selftest operation. 

13/0xd 

Commands Cleared Unit 
Attention 

N.A. 

None 

Another originator sent commands to the array that 
resulted in commands being cleared for the current 
originator. 

14/0x0e 

Mode Parameters Changed 
Unit Attention 

N.A. 

None 

Another initiator sent commands to the array that 
resulted in shared mode parameters being changed 
for the current initiator. 

15/0x0f 

Unconfigured LUN 

N.A. 

None 

The LUN to which the command was sent is 
currently not configured for use. 

16/0x10 

Invalid Target LUN 

N.A. 

None 

The subsystem does not support the LUN that was 
specified in the most recent command. The LUN is 
the target of the requested action. 

17/0x11 

Invalid Source LUN 

N.A. 

None 

The subsystem does not support the LUN that was 
specified in the most recent command. The LUN is 
the source of the requested action. 

18/0x12 

Not Enough Space 

Ignore 

None 

A write command had to move data in order to find 
enough space to complete.  Errors were encountered 
during this process which precluded the controller 
from providing enough space for the write.  This 
would generally result from multiple failing or 
missing drives.  This failure can also result from 
faulty space management logic in the controller. 

19/0x13 

Command Illegal In Current 
State 

N.A. 

None 

The current subsystem state precludes processing of 
the requested command. 

20/0x14 

Becoming Ready 

N.A. 

None 

The subsystem is not ready to process the command 
that was received.  However, it is in the process of 
becoming ready and will be able to process that 
command soon. 

21/0x15 

Recovered With Low Level 
Retries 

Y Ignore Disk, 

controller, disk 
interface 

On a previous attempt(s), the drive failed the I/O. 
The PDD retried the I/O and the drive returned good 
status.  PDD stands for Physical Device Driver.  
Specifically this error indicates that the RAID 
implementation was not involved in the retries. 

22/0x16 

Recovered By Disk Drive 

See information 

provided by 

drive vendor 

Disk Drive 

The disk drive returned a status of 
CHECK_CONDITION, RECOVERED_ERROR. 

23/0x17 

Disk Drive Media Error 

See information 

Disk Drive 

The disk drive returned a status of 

Содержание StorageWorks 7100 - Virtual Array

Страница 1: ... array changes to the configuration of the array performance data port error statistics Table 1 lists all event codes that can appear in the controller log event pages The table also includes events that are not logged but can still generate SCSI sense data Appropriate corrective action is included for all events that require it Many events are informational and require no action on the part of th...

Страница 2: ...are error during a selftest operation 13 0xd Commands Cleared Unit Attention N N A None N Another originator sent commands to the array that resulted in commands being cleared for the current originator 14 0x0e Mode Parameters Changed Unit Attention N N A None N Another initiator sent commands to the array that resulted in shared mode parameters being changed for the current initiator 15 0x0f Unco...

Страница 3: ...A None Y A disk drive failed the reconfiguration attempt TUR inquiry mode sense mode select read capacity The PDD attempted a device reconfiguration after the device was reset during the normal course of operation i e not during a hotplug of this drive but possibly during a hotplug of another drive If the device reconfiguration fails the PDD flushes all non passthru I Os from its waiting queue wit...

Страница 4: ... 0x2c Invalid RG ID N N A None N A command that specifies an Redundancy Group ID specified one that is invalid for the current subsystem configuration 45 0x2d Shutdown Failed N N A None N CFM could not shutdown the subsystem because no volume set members were present all members missing 46 0x2e Not Enough Space Y Ignore See accompanying errors None Y A write command had to move data in order to fi...

Страница 5: ...See accompanying errors None N R1 detected that the devices necessary for a write were not available for access before the access was attempted This can apply to an initial attempt to write or to a retry 59 0x3b Disk Interface Error Y N A None Y An error occurred on a disk interface command 60 0x3c Unsupported feature N Ignore Device Management error None Y An attempt was made to install a license...

Страница 6: ...uld retry the operation 78 0x4e Silent Disk Drive Error Recovery N N A None N On a previous attempt s the drive failed the I O Usually due to hot plug The PDD retried the I O and the drive returned good status We do not log a recovered error because the original error was not logged We report GOOD status to the host 79 0x4f Check Condition From Disk Drive With No Sense Y Single Occurrence Disk Dri...

Страница 7: ...troller does not have sufficient information to determine the extent of the damage 94 0x5e Volume Set Missing During Recovery Y ignore operator error None Y The volume set referenced in a recover command is not present in the subsystem If a NULL volume set was referenced then this error indicates that no members of any volume set were present This error can also result from imcompatible stamp vers...

Страница 8: ...ermission to access LUN None Y The Host attempted to perform an operation on LUN without having an appropriate access permission 112 0x70 Host can not be authenticated to access LUN Security map Y Ignore Provide correct password None N The Host failed the authentication for access to LUN Security map because the password that it presented is incorrect 113 0x71 Limit to Maximum number of Principals...

Страница 9: ...pected error 131 0x83 Disk Interface Command Failed Y N A None N A command to a backend device failed due to an error that does not include sense data from the device 132 0x84 Host is not authorized to access LUN Y Ignore Host doesn t have permission to access LUN None Y LUN Security Authoriztion failed Host attempted to perform an operation on a LUN without having an appropriate access permission...

Страница 10: ...leted successfully This message follows the message 267 0x10b Insufficient Space To Start Rebuild Y Ignore See accompanying errors None N here is insufficient disk space for rebuild to execute This message followsthe message and may follow the REBUILD message 268 0x10c Rebuild Failed Y Ignore See accompanying errors None N ebuild has failed to complete due to multiple disk failures or a controller...

Страница 11: ...ification succeeds 279 0x117 Disk Set Attached Y Ignore Operator activity None N This error code indicates the system state change consisting of attachment to a new volume set has occurred This occurs after every format subsystem and whenever a power on or reset occurs while the controller is not attached to a volume set In some cases the currently attached volume set may be empty 280 0x118 Reset ...

Страница 12: ...ta may then be successfully migrated 290 0x122 Warm Boot IO Expander Fault Y Ignore if recovered by power cycle Controller Y This error code indicates that the IO Expander containing the warm boot bit did not power on in the correct default condition or that attempts to set the warm boot bit in the IO Expander failed 291 0x123 Disk Set Detached Y Ignore Operator Host activity None N This is a syst...

Страница 13: ...r This error is logged only once per power on 303 0x12f No Interrupts From Other Controller Y Single Occurrance Controller Backplane N he other controller interrupt seems to be broken The timer interrupt fired multiple times with new communication messages but no other controller interrupts were present This error is logged only once per power on 304 0x130 Disk Interface Disconnect Y Ignore Disk c...

Страница 14: ...an expected 319 0x13f Disk Interface Overrun Event Y Single Occurrance not with other entries Disk controller disk interface N An attached disk sent received more data than expected 320 0x140 Disk Interface Timeout Event Y 2 occurrances per hot plug insert or removal Disk controller disk interface N A command to an attached disk did not complete within the allotted time 321 0x141 Controller ECC Mi...

Страница 15: ...6 0x150 Disk Interface State Event Y Single Occurrance not with other entries Controller disk disk interface N The disk interface controller and or software state information was incorrect for observed interface activity 337 0x151 Uncorrectable ECC Error During Initialization Y 1 in 6 months if no operator activity SIMM Controller N This error code indicates that the system experienced a unrecover...

Страница 16: ...50 0x15e RAM Version Mismatch Y N A None N The upload routine was unable to upload part of the disk NVRAM image because the current firmware does not support that use of RAM Most likely an older version of firmware is trying to upload a disk image posted by some other firmware version 351 0x15f Disk Format Version Mismatch Y N A None N The NVRAM format of the disks does not match the format used b...

Страница 17: ... This error code indicates that some non fatal error appeared in the shared memory error queue The two words of this queue entry will be placed in the log entry extended info area 363 0x16b Shared memory controller error Y Ignore if recovered by reset or power cycle Controller N This error code indicates that some fatal error appeared in the shared memory controller error queue The two words of th...

Страница 18: ...376 0x178 Frontend Fibre Channel Event Y Ignore None N This error code indicates that the Front End Fibre Channel port had an event that it has logged Specific information about the event is placed in the extended info area of the log 377 0x179 Frontend Services Event Y Ignore None N This error code indicates that a Front End Services FES event has occurred and has been logged Specific information...

Страница 19: ...en inserted into the enclosure 388 0x184 Internal drive removed Y Disk internal to the controller enclosure N An internal disk has been removed from the enclosure 389 0x185 Internal drive requesting port bypass Y Disk internal to the controller enclosure N An internal disk is requested that its FC port be bypassed 390 0x186 Internal drive has stopped requesting port bypass Y Disk internal to the c...

Страница 20: ...ler will be failed 419 0x1a3 VSC055 Interrupt Clear Failed Y VSC055 IO Expander Chip Y An attempt to clear an interrupt on the VSC055 indicated in the event extended information has failed The controller will be failed 420 0x1a4 Power supply was inserted Y Power Supply N The power supply has been inserted into the enclosure 421 0x1a5 Power supply status is GOOD Y Power Supply N The power supply ha...

Страница 21: ... charge is equal or higher than a specified threshold value 448 0x1c0 NVRAM battery status is UNKNOWN Y NVRAM battery N The status of the NVRAM battery is unknown This may be due to the firmware not being able to communicate with the battery 449 0x1c1 TWSI bus has been requested by another module Y Ignore unless occurring frequently Controller battery power supply N The battery management firmware...

Страница 22: ...wn Y Midplane Y During a request for a new lun WWN the firmware was not able to read from either of the midplane eeproms This is can be due to a variety of TWSI failures or the eeprom failing The eeprom can only create 2 000 trillion 2 quadrillion LUN s If this limit has been exceeded the midplane must be replaced 470 0x1d6 Firmware clone complete Y N A N Cloning of firmware to the other controlle...

Страница 23: ...tected an internal error 489 0x1e9 abterm reset Y controller N This event code indicates that the controller reset due to an abnormal termination in the firmware 490 0x1ea front panel reset Y controller N This event code indicates that the controller reset due to a request through the front panel 491 0x1eb host reset Y controller N This event code indicates that the controller reset due to a reque...

Страница 24: ...ta on the two eeproms at a given location was different This problem is usually fixed if the firmware can write to the eeproms 510 0x1fe FC Signal Detect Interrupt Y VSC7130 PBC Dual Repeater Chip N An interrupt on one of the VSC7130 port bypass control signal detect chips has occurred See the extended information for details 511 0x1ff Dual controller clock sync error Y controller N An interrupt f...

Страница 25: ...Y Ignore unless no Operator activity Disk Drive Back End FC Link N An AutoFormat event was logged this is caused either by a backend format of an internal drive beginning or completing Look as the associated data for drive and status 532 0x214 Power supply is not connected to an AC source Y Power Supply Y This warning indicates that the power supply is not connected to an AC source 533 0x215 Some ...

Страница 26: ...out Y Ignore Lab only none N The cross controller lock module failed to grant the decoder s lock in exclusive mode within the allowed period after an obtain request was deferred This may indicate a deadlock in the system or that the system is too busy 552 0x228 Decoder lock request was deferred Y Ignore Lab only none N The cross controller lock module deferred a request to obtain the decoder s loc...

Страница 27: ... mode parameters region contains a revision that is older than the revision expected by current firmware As a result some mode parameters were set to their default values since there was no saved value present in the EEPROM 577 0x241 Start multi disk loss scan Y Ignore should be other prior failure events controller N A backend scan was started to detect a multiple disk loss condition because of a...

Отзывы: