Event
Number
(dec/hex)
Event
Name
Logged?
Predictive
Maintenance
Implication
Suspected
Components
Mf
g Fail?
Description
EH
The JEM object has completed its deletion.
481/0x1e1
LCC_JEM_DELETE_PENDI
NG_EH
Y
LCC/ESD
N
Topology Manager requested a delete of a JEM
when the JEM has an outstanding I/O. The deletion
is pending on the completion/failure of the
outstanding I/O. Any qued I/O would be aborted.
482/0x1e2
TWSI bus retry
Y
Ignore, unless
occurring
frequently.
Controller,
midplane,
power supply,
battery
N
A transaction on the two-wire serial bus failed and
was retried.
483/0x1e3
Keyswitch error
Y
Keyswitch
circuitry
Y
This error code indicates that a controller was
removed from the system without generating a park
interrupt to the remaining controller when inter-
controller communication was enabled. The
operating state of the logging controller is placed in
the extended info area. If the removed controller
was in use, the remaining controller will go through
a short reset after logging this error.
484/0x1e4
Power-on reset
Y
controller
N
This event code indicates that a controller went
through a power-on reset. This is a normal power-on
condition.
485/0x1e5
Hot plug reset
Y
controller
N
This event code indicates that a controller reset was
initiated due to a controller insertion or removal.
486/0x1e6
Heartbeat timeout reset
Y
controller
N
This event code indicates that a controller reset was
initiated due to a controller heartbeat timeout. One
of the controllers in the system failed to check-in
with the controller heartbeat checking module.
487/0x1e7
software fault reset
Y
controller
N
This event code indicates that the firmware
performed an illegal action which resulted in a
software fault and reset.
488/0x1e8
hardware fault reset
Y
controller
N
This event code indicates that the hardware
performed an illegal action which resulted in a
hardware fault and reset. This could mean that the
hardware generated an unrecognized interrupt vector
or that the shared-memory controller detected an
internal error.
489/0x1e9
abterm reset
Y
controller
N
This event code indicates that the controller reset
due to an abnormal termination in the firmware.
490/0x1ea
front panel reset
Y
controller
N
This event code indicates that the controller reset
due to a request through the front panel.
491/0x1eb
host reset
Y
controller
N
This event code indicates that the controller reset
due to a request from the host.
492/0x1ec
firmware download reset
Y
controller
N
This event code indicates that the controller reset
due to the completion of a successful firmware
download.
493/0x1ed
controller failover reset
Y
replace the failed
controller
controller
Y
This event code indicates that the controller reset
due to the failure of the other controller in the
enclosure.
494/0x1ee
memory error reset
Y
controller
N
This event code indicates that the controller reset
due to a memory error.
495/0x1ef
dual controller comm failure
Y
Ignore unless a
dual controller
system is in a
communication
failure state
controller
Y
This event code indicates that the controller reset
due to a dual controller communication failure. If
the controllers are able to communicate after the
reset, this error can be ignored.
496/0x1f0
Controller Removed
Y
controller
N
This event code indicates that the controller was
removed from the enclosure with the power on.
This is a normal entry for a controller that was hot-
removed previously.
497/0x1f1
reset requested by other
controller
Y
controller
N
This event code indicates that the controller reset
due to a reset request from the other controller.
498/0x1f2
Shared-memory error reset
Y
controller
N
This event code indicates that the controller reset in
order to recover from an error detected in shared
memory.
499/0x1f3
Controller reset
Y
controller
N
This event code indicates that the controller reset for
an unknown reason.
500/0x1f4
Current mode parameters were
saved
Y
controller
N
This event code indicates that the current mode
parameters were saved to the saved mode
parameters without changing them.
501/0x1f5
Unsupported mode parameter
region revision
Y
controller
N
An access to the mode parameter region of the
chassis NV memory found data with a format