Troubleshooting Guide
POST Error Messages
1782-Disk Controller
Failure
Hard drive circuitry
error.
1. Run Computer Setup.
2. Clear CMOS. (See
Appendix B,
“Password Security and Resetting
CMOS.”
)
3. Check cable seating/jumper settings.
4. Run hard drive diagnostics.
5. Disconnect additional drives.
6. Replace the hard drive.
7. Replace the system board.
1800-Tempera-
ture Alert
Internal temperature
exceeds specification.
1. Check that computer air vents are not
blocked and cooling fan is running.
2. Verify processor speed selection.
3. Replace the processor.
4. Replace the system board.
1801-Microcode
Patch Error
Processor is not
supported by
ROM BIOS.
Upgrade BIOS to proper version.
Invalid Electronic
Serial Number
Electronic serial number
has become corrupted.
1. Run Computer Setup. If Setup already
has data in the field or will not allow
the serial number to be entered,
download from
www.hp.com
and run SP5572.EXE (SNZERO.EXE).
2. Run Computer
Setup and try to enter
serial number under Security, System
IDs, then save changes.
ECC Multiple Bit
Error Detected in
Memory Module
Chipset has detected
more than one bad bit
in a 64-bit quadword of
the memory array.
Replace the memory module.
Parity Check 2
Parity RAM failure.
Run Computer Setup and Diagnostic
utilities.
Numeric Codes and Text Messages
(Continued)
Code/Message
Probable Cause
Recommended Action