CAUTION:
Heatsinks specified for processor 1 and 2 are not interchangeable. Be sure to note the
appropriate orientation on the heatsink label.
CAUTION:
Heatsink retaining screws should be tightened or loosened in diagonally opposite pairs (in an
"X" pattern). Do not overtighten the screws as this can damage the board, connectors, or
screws.
6.
Install the heatsink:
a.
Position the heatsink on the processor backplate.
b.
Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws.
c.
Finish the installation by completely tightening the screws in the same sequence.
7.
Install the air baffle.
8.
If the 4:1 riser cable signal or Smart Storage Battery are installed in the air baffle, reconnect the
cable to the risers. For more information, see "Cabling (
,
)".
9.
Install the access panel.
10.
Install the server into the chassis.
11.
Connect all peripheral cables to the server .
12.
Power up the server .
Expansion board
Expansion boards supported with this server include any board installed in the PCIe riser modules,
including controllers, NIC cards, and GPU accelerators.
For more information on GPU accelerators, see "
For more information on the HPE Smart Array P542D Smart Array controller module, see "
Array P542D Smart Array controller mezzanine card and storage riser bracket
76
Expansion board
Содержание ProLiant XL270d Gen9
Страница 12: ...12 Customer self repair ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...14 Customer self repair ...
Страница 15: ...Customer self repair 15 ...
Страница 118: ... Slot 10 118 Cabling ...
Страница 120: ...PCI riser module signal cabling 4 1 riser signal cable 120 PCI riser module signal cabling ...
Страница 121: ...8 1 riser sideband cable 8 1 riser sideband cable 121 ...