13.
Reinstall the GPU cover.
14.
Install the GPU.
a.
Slide the GPU halfway into the server.
b.
Connect the power cable to the GPU.
c.
Install the GPU into the server and tighten the thumbscrew.
15.
Install the side panel.
16.
Install the access panel.
17.
Install the server into the chassis.
18.
Connect all peripheral cables to the server .
19.
Power up the server .
Replacing the failed NVIDIA GPU accelerator
NOTE:
NVIDIA Tesla P4 GPU does not have any power cables.
Procedure
1.
Back up all server data.
2.
3.
Disconnect all peripheral cables from the server front panel.
4.
Remove the server from the chassis
.
5.
Place the server on a sturdy, level surface.
6.
.
50
Replacing the failed NVIDIA GPU accelerator