Item
LED
Status
Definition
Flashing green
The drive is rebuilding or performing
a RAID migration, strip size
migration, capacity expansion, or
logical drive extension, or is erasing.
Flashing amber/green
The drive is a member of one or
more logical drives and predicts the
drive will fail.
Flashing amber
The drive is not configured and
predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a
RAID controller.
IMPORTANT:
The Dynamic Smart Array B140i Controller is only available in UEFI Boot Mode. It cannot be
enabled in Legacy BIOS Boot Mode. If the B140i controller is disabled, drives connected to the
system board Mini-SAS connectors operate in AHCI or Legacy mode. Under this condition:
• The drives cannot be a part of a hardware RAID or a logical drive.
• The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled.
Use BIOS/Platform Configuration (RBSU) in the
B140i controller (System Configuration
®
BIOS/Platform Configuration (RBSU)
®
System Options
®
SATA Controller Options
®
Embedded SATA Configuration).
GPU accelerator numbering
• Server left GPU accelerator numbering
106
GPU accelerator numbering
Содержание ProLiant XL270d Gen9
Страница 12: ...12 Customer self repair ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...14 Customer self repair ...
Страница 15: ...Customer self repair 15 ...
Страница 118: ... Slot 10 118 Cabling ...
Страница 120: ...PCI riser module signal cabling 4 1 riser signal cable 120 PCI riser module signal cabling ...
Страница 121: ...8 1 riser sideband cable 8 1 riser sideband cable 121 ...