Hardware options installation 73
5.
Remove the access panel (on page
25
).
6.
If installed, remove the PCI air baffle (on page
27
).
7.
Remove the system air baffle (on page
28
).
8.
If a Smart Array controller is installed, disconnect the capacitor pack cable from it, and then remove the
capacitor pack holder from the server.
9.
Remove any installed full-length PCI expansion cards ("
Remove the full-length expansion board
" on
page
29
).
10.
Remove the fan modules and the fan blank (on page
30
).
11.
Disconnect the power cables from the system board, drive cages, and optical drive.
12.
Remove the integrated power supply.
13.
Install the redundant power supply assembly:
a.
Insert the redundant power supply assembly into the server chassis.