Removal and replacement procedures
75
8.
Close the ejector lever, and lock the locking switch.
9.
Power up the server.
10.
Reference the memory board LEDs ("Memory board components and LEDs"
on page
94
) to be sure that the memory board is functioning properly.
Removing a memory board
1.
Power down the server if the server is not configured for hot-plug RAID
memory or hot-plug mirrored memory.
CAUTION: Only memory boards with a green Removable LED can
be removed. Do not attempt to remove any memory board with the
Removable LED off.
CAUTION: To prevent system failure, do not remove the memory
board from the server until the board status LED stops flashing.
2.
Unlock the locking switch, and open the release latch.
3.
Use the ejector lever to pull the memory board out of the server.
NOTE: While the memory board with the failed or degraded DIMM
is being replaced, the server continues to read and write from the
operational memory board.