HP ProLiant DL580 Generation 3 Server Maintenance and Service Guide
2.
Reseat the processor in socket 1.
3.
Reseat the remaining processors, rebooting after each installation to identify
any failed processors.
IMPORTANT: Populate the processors in the following order: 1, 2,
4, 3.
IMPORTANT: Always install a PPM when you install a processor.
The system fails to boot if the PPM is missing.
4.
Replace the processor in socket 1.
5.
Replace the processor board, if applicable.
6.
Replace the system board.
IMPORTANT: If replacing the system board or clearing NVRAM,
you must re-enter the server serial number through RBSU ("Re-entering
the server serial number and product ID" on page
41
).
Memory-related port 85 codes
Memory-related port 85 codes display on the media board in the format 4xh.
IMPORTANT: Reboot the server after completing each numbered
step. If the error condition continues, proceed with the next step.
To troubleshoot memory-related error codes:
1.
Check the memory board LEDs ("Memory board components and LEDs" on
page
94
) for any identified errors or failed DIMMs, and take corrective
action.
2.
Bring the server to base configuration by removing all components that are
not required by the server to complete POST. This process can include
removing all:
–
Expansion boards ("Removing a non-hot-plug expansion board" on page
33
, "Removing a PCI-X Hot Plug expansion board" on page
57
)
–
Processors ("Removing a processor" on page
26
), except the processor
installed in socket 1
IMPORTANT: Processor socket 1 and PPM slot 1 must be
populated at all times or the server will not function properly.