128
HP ProLiant DL580 Generation 3 Server Maintenance and Service Guide
Power supply output
910 W (low line)
1300 W (high line)
Environmental specifications
Temperature range*
Specification
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping
-40
°
C to 70
°
C (-40
°
F to 158
°
F)
Maximum wet bulb temperature 28
°
C (82.4
°
F)
Relative humidity
(noncondensing)**
Specification
Operating
10% to 90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m
(1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C
(113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.
Hot-plug power supply calculations
For hot-plug power supply specifications and calculators to determine electrical
and heat loading for the server, refer to the HP Enterprise Configurator website
(
http://h30099.www3.hp.com/configurator/
).
Содержание Proliant DL580
Страница 6: ......
Страница 90: ......
Страница 109: ...Server component identification 109 Simplex mode Duplex mode ...
Страница 118: ......
Страница 125: ...Server cabling 125 9 Remove the power switch cable assembly To replace the component reverse the removal procedure ...
Страница 126: ......
Страница 134: ......