36
HP ProLiant DL580 Generation 3 Server Maintenance and Service Guide
6.
Loosen the thumbscrews, and lift the mezzanine board from the server.
CAUTION: To prevent improper cooling and thermal damage, do
not operate the server unless all expansion slots have either an
expansion slot cover or an expansion board installed.
To replace the component, reverse the removal procedure.
Recovering data from the BBWC
If the server fails, you can recover any data temporarily trapped in the BBWC by
using the following procedure.
CAUTION: Before starting this procedure, read the information
about protecting against electrostatic discharge ("Preventing
electrostatic discharge" on page
14
).
1.
Perform one of the following:
–
Set up a recovery server station using an identical server model. Do not
install any internal drives or BBWC in this server. (This option is
preferred.)
–
Find a server that has enough empty drive bays to accommodate all the
drives from the failed server and that meets all the other requirements for
drive and array migration.