HP Array Configuration Utility 62
When you use the
drives
parameter you can list each drive individually, you can specify a drive range, or
you can specify both a range and some individual drives. A drive range can span ports, boxes, and bays.
If you specify individual drives, they do not have to form a continuous sequence. If you specify a range, the
CLI automatically excludes from the target any drive in the range that is unavailable (for example, a drive is
excluded if it already belongs to an array, is a spare, has too small a capacity, or has failed).
If you want to specify an existing array by its drives rather than by array ID, then all of the drives that you
specify must belong to the same array, and none of the drives in the array can be omitted.
Example commands:
ctrl slot=5 create type=ld drives=1:0,1:1,1:3 raid=adg
ctrl slot=5 create type=ld drives=1:1-1:3 raid=adg
ctrl slot=5 create type=ld drives=1:7,1:10-2:5,2:8-2:12 raid=adg
ctrl slot=5 array A create type=ld size=330 raid=adg
The following pair of commands demonstrates how the
drives
parameter can be used in a batch file to
create two logical drives on the same array, one of 330 MB and the other of 450 MB:
ctrl slot=2 create type=ld drives=1:1-1:6 size=330 raid=adg
ctrl slot=2 create type=ld drives=1:1-1:6 size=450 raid=5
Sample scenario
Consider a situation in which you want to create two arrays. One of these arrays needs two logical drives,
while the other needs only one.
First, determine what physical drives are available and what their properties are:
=> ctrl ch="Lab 4" pd all show
For this sample scenario, the screen response is:
MSA1000 at Lab 4
unassigned
physicaldrive 1:12 (box 1:bay12, Parallel SCSI, 36.4 GB, OK)
physicaldrive 1:13 (box 1:bay13, Parallel SCSI, 9.1 GB, OK)
physicaldrive 1:14 (box 1:bay14, Parallel SCSI, 9.1 GB, OK)
Knowing this information, you can now create the first array with one logical drive:
=> ctrl ch="Lab 4" create type=ld drives=1:12
Now, verify that the array has been created:
=> ctrl ch="Lab 4" pd all show
In this case, the screen response is:
MSA1000 at Lab 4
array A
physicaldrive 1:12 (box 1:bay12, Parallel SCSI, 36.4 GB, OK)
unassigned
physicaldrive 1:13 (box 1:bay13, Parallel SCSI, 9.1 GB, OK)
physicaldrive 1:14 (box 1:bay14, Parallel SCSI, 9.1 GB, OK)
The second array is to be created on the two remaining physical drives. Before creating this array, determine
what RAID options are available for these drives:
=> ctrl ch="Lab 4" create type=ld drives=1:13,1:14 size=300 raid=?
The response in this case is:
Available options are:
0