The Configuration Menu
RADIUS Server Configuration
Command:
/cfg/sys/radius
[RADIUS Server Menu]
prisrv - Set primary RADIUS server address
secsrv - Set secondary RADIUS server address
secret - Set RADIUS secret
port - Set RADIUS port
retries - Set RADIUS server retries
timeout - Set RADIUS server timeout
telnet - Enable or disable RADIUS backdoor for telnet
on - Turn RADIUS authentication ON
off - Turn RADIUS authentication OFF
cur - Display current RADIUS configuration
NOTE:
Refer to the
HP ProLiant BL p-Class GbE2 Interconnect Switch Application Guide
for
information on RADIUS.
The following table describes the
RADIUS Server Configuration Menu
options.
Table 6-5: RADIUS Server Configuration Menu Options
Command Description
prisrv
<IP address>
Sets the primary RADIUS server address.
secsrv
<IP address>
Sets the secondary RADIUS server address.
secret
<1-32 character secret>
This is the shared secret between the GbE2
Interconnect Switch and the RADIUS server(s).
port
<RADIUS port configure,
default 1645>
Enter the number of the User Datagram
Protocol (UDP) port to be configured, between
1500-3000. The default is 1645.
retries
<RADIUS server retries>
Sets the number of failed authentication
requests before switching to a different RADIUS
server. The default is 3 requests.
timeout
<RADIUS server timeout
seconds>
Sets the amount of time, in seconds, before a
RADIUS server authentication attempt is
considered to have failed. The default is 3
seconds.
telnet disable|enable
Enables or disables the RADIUS backdoor for
Telnet. Telnet also applies to SSH/SCP
connections. The default is disable.
on
Enables the RADIUS server.
off
Disables the RADIUS server. This is the default.
cur
Displays the current RADIUS server
parameters.
IMPORTANT:
If RADIUS is enabled, you are required to login using RADIUS when doing Telnet. If a
RADIUS server is not available and the Telnet backdoor is enabled, type in
noradius
as a backdoor to
bypass RADIUS checking, and use the administrator password to log into the GbE2 Interconnect
Switch. Using
noradius
is only allowed if the RADIUS server is not available.
HP ProLiant BL p-Class GbE2 Interconnect Switch Command Reference Guide
6-9
HP CONFIDENTIAL
Codename: Strawberry Part Number: 331404-001 Last Saved On: 7/17/03 12:57 PM