Select
Standard Configuration
to quickly configure a controller. Choosing
Standard
Configuration
is the fastest way to configure a controller but requires an intermediate to
advanced level of knowledge concerning storage. The Standard Configuration path offers
the least amount of help or step-by-step guides and does not provide a FAQ panel, assuming
the user knows exactly what they would like to accomplish and are very familiar with the
concepts required to complete the task.
The default method is the standard configuration method. The steps that follow are for
creating an array using the standard configuration mode.
7.
Click
Create Array
.
8.
Select all of the drives to be included in the array, and then click
OK
.
9.
Select the array that was just created, and then click
Create logical Drive
at the right.
10.
Select the desired Fault Tolerance, Stripe Size, and Size of the logical disk, and then click
OK
.
The Fault tolerance level depends on the amount of disks selected when the array was created.
A minimum of two disks is required for a RAID 0+1 configuration, three disks for a RAID 5
configuration, and four disks for a RAID 5 ADG configuration.
11.
After all logical disks have been created, click
Save
.
12.
Click
Exit ACU
to exit the ACU session.
ACU guidelines
•
Do not modify Array A off of the Smart Array controller as it contains the storage server OS.
•
Spanning more than 14 disks with a RAID 5 volume is not recommended.
•
Designate spares for RAID sets to provide greater protection against failures.
•
RAID sets cannot span controllers.
•
A single array can contain multiple logical drives of varying RAID settings.
•
Extending and Expanding Arrays and Logical Drives is supported.
•
RAID migration is supported.
Managing disks on configurable storage servers
From the
Disks
tab of the WebUI, click
Disks
. The page displays the physical disks that are associated
with the storage server and the volumes that are created on them. Multiple volumes can appear on
multiple disks depending on whether the volumes are simple, spanned, or multi-volumes/partitions exist.
The page also displays the type of disk (basic or dynamic).
HP ProLiant Storage Server administration guide
37
Содержание ProLiant 300 Series
Страница 11: ...115 NIC Teaming status 215 HP ProLiant Storage Server administration guide xi ...
Страница 16: ...16 About this Guide ...
Страница 78: ...78 Shadow Copies ...
Страница 124: ...124 Folder Printer and Share Management ...
Страница 170: ...170 Remote Access Methods and Monitoring ...
Страница 208: ...Figure 109 HP Network Teaming Properties dialog box 2 Highlight the NICs to team 3 Click Team 208 NIC Teaming ...