59
Chapter 2
MIC BIOS Messages
Watchdog timer expired
Severity
Error
Description
The MIC BIOS monitors progress during the startup process. If there is no activity for an
extended period of time, this message is displayed and the system is automatically rebooted.
This could occur due to System BIOS incompatibilities, software faults, or hardware failures.
Action
•
Verify that the hardware is functioning properly by running the MIC BIOS client-server
diagnostics between the CE and the IOP providing startup services.
•
Consult the startup IOP’s event log for possible additional information.
•
If the error persists, contact your service provider for assistance.