Chapter 13
MtcMon Messages
208
IOPn.MtcMon FRU: Local hardware fault on IOPx.
Variables
x – the ID of the IOP with the hardware error.
Severity
Error
Description
A fault was detected on the system disk used by the specified IOP, and the IOP has been
removed from service. (Note that usually the IOP reporting the message is not the same as the
IOP with the problem, since an IOP with a hardware error is usually unable to report an error
to the event log.)
Action
•
Reboot IOPx in maintenance or Offline I/O Processor mode.
•
Run CHKDSK or other Windows NT diagnostics in order to determine whether the device
is faulty.
•
Examine the IOP Event Viewer log for device-specific errors.
•
Replace the disk or adapter if necessary. If the system disk failed, you may need to
reinstall the Windows NT operating system and the Endurance software.
•
Reboot the IOP.
IOPn.MtcMon FRU: Processing capability failure on unspecified CE.
Severity
Error
Description
An error occurred that originated from a CE, but the details were not sufficient to determine
which CE caused the condition.
Note:
The CE removed as a result of this error may not be the source of the fault
The failure may have been caused by memory or other platform errors on a CE that were not
detected at the time of the failure. However, in these cases, you may often have previous errors,
either fatal or non-fatal, reported against one of the CEs. Examine the CE operating system or
IOP event logs to locate these errors.
Related Messages
IOPn.MtcMon FRU: Uncorrectable memory error on CEx
IOPn.MtcMon FRU: Uncorrectable platform error on CEx
IOPn.MtcMon Fault Handler status: CEx has reported n memory error(s).
IOPn.MtcMon Fault Handler status: CEx has reported n platform error(s).
Action
•
Run diagnostics on each CE to determine if one of them is faulty.
•
If this condition persists without other errors, contact your service provider for assistance.
•
Examine the CE or IOP error logs. If there are several recent memory errors reported
against one of the CEs, then replace the memory. If there are several recent platform errors
reported against one of the CEs, then consider replacing the CE.
Содержание NetServer AA 4000
Страница 1: ...HP NetServer AA Solution Messages HP Part Number 5969 5966 Printed in September 2000 ...
Страница 6: ...Contents vi ...
Страница 8: ...Tables viii ...
Страница 52: ...Chapter 1 Introduction 42 ...
Страница 70: ...Chapter 2 MIC BIOS Messages 60 ...
Страница 98: ...Chapter 4 MtcCEX Messages 88 ...
Страница 119: ...109 Chapter 6 MtcDsl Messages ...
Страница 120: ...Chapter 6 MtcDsl Messages 110 ...
Страница 154: ...Chapter 8 MtcEvtP Messages 144 ...
Страница 162: ...Chapter 9 MtcFLOP and MtcFLOR Messages 152 ...
Страница 166: ...Chapter 10 MtcIopDm Messages 156 ...
Страница 372: ...Chapter 16 MtcVidP Messages 362 ...
Страница 378: ...Chapter 17 MtcVnP Messages 368 ...