Chapter 6
Replacing Parts
92
Replacing the I/O Fans
The I/O fans are mounted on the PCI board guide, just forward of the PCI sockets on the I/O board. These
fans are individually replaceable and may be hot swapped.
CAUTION
Do not run this NetServer for more than 60 minutes without all covers in place. Any
component being replaced must be removed and a replacement installed within this
60-minute time window. If you feel that you cannot, in your estimate, replace any
particular component within this time, first turn off power to the system and then
replace the component. Failure to replace the covers within 60 minutes may result in
damage to system components due to lack of cooling airflow.
Follow these instructions to remove and replace the I/O fans:
1. Back up the hard disk drive(s) and save the configuration.
2. If necessary, shutdown the network operating system.
3. Turn off the HP NetServer and display.
4. Disconnect all telephone cables and power cords.
5. Remove cover.
6. Remove the fan by pressing in on the tab and sliding the fan out of the chassis (see figure
below).
Removing the I/O Fans
Replace the fan by using the above procedure in reverse.
Replacing the Processor Fans
The processor fans are individually mounted just to the rear of the system board assembly. These fans are
individually replacable and may be hot-swapped.
Содержание LH6000r - NetServer - 0 MB RAM
Страница 1: ...HP NetServer LH 6000 LH 6000r Service Manual Online Version 1 1 Last Updated May 2000 ...
Страница 22: ...Chapter 1 General Information 16 ...
Страница 39: ...33 3 Parts Information Exploded View Covers Bezel Front Panel 1 1 2 3 15 4 7 9 10 8 11 7 5 13 6 12 14 ...
Страница 41: ...Chapter 3 Parts Information 35 Exploded View Mass Storage 45 44 43 46 47 32 33 35 34 36 37 38 39 40 41 42 40 ...
Страница 43: ...Chapter 3 Parts Information 37 Exploded View Exhaust Fans System Board Assembly See exploded view 65 66 59 ...
Страница 110: ...Chapter 6 Replacing Parts 104 ...