Chapter 6
Replacing Parts
90
CAUTION
Do not touch the components as you push the VRM down into the slot.
3. Gently insert the VRM into the socket.
4. Re-install the system board assembly into the chassis.
Replacing the Power Supply Fans
The power supply fans are mounted on removable brackets just forward of the power supply cage(s). Each
bracket contains two fans. The fans are not individually replaceable; you must replace them both, and the
bracket, as a unit. These units may be hot-swapped.
CAUTION
Do not run this NetServer for more than 60 minutes without all covers in place. Any
component being replaced must be removed and a replacement installed within this
60-minute time window. If you feel that you cannot, in your estimate, replace any
particular component within this time, first turn off power to the system and then
replace the component. Failure to replace the covers within 60 minutes may result in
damage to system components due to lack of cooling air.
Follow these instructions to remove and replace the power supply fans:
1. Back up the hard disk drive(s) and save the configuration.
2. If necessary, shutdown the network operating system.
3. Turn off the HP NetServer and display.
4. Disconnect all telephone cables and power cords.
5. Remove cover.
6. Lift the ejection handle to release the fan bracket from the chassis. Remove the bracket from
the chassis.
Содержание LH6000r - NetServer - 0 MB RAM
Страница 1: ...HP NetServer LH 6000 LH 6000r Service Manual Online Version 1 1 Last Updated May 2000 ...
Страница 22: ...Chapter 1 General Information 16 ...
Страница 39: ...33 3 Parts Information Exploded View Covers Bezel Front Panel 1 1 2 3 15 4 7 9 10 8 11 7 5 13 6 12 14 ...
Страница 41: ...Chapter 3 Parts Information 35 Exploded View Mass Storage 45 44 43 46 47 32 33 35 34 36 37 38 39 40 41 42 40 ...
Страница 43: ...Chapter 3 Parts Information 37 Exploded View Exhaust Fans System Board Assembly See exploded view 65 66 59 ...
Страница 110: ...Chapter 6 Replacing Parts 104 ...