Chapter 2
System Information
23
•
Non-hot-swap, single-ended SCSI devices installed in the two empty trays adjacent to the CD-
ROM drive
•
Hot-swap Ultra-2 SCSI hard disk drives installed in the hot-swap mass storage cages
Use only high-performance, Ultra-2, hot-swap drives in the integral hot-swap mass storage cages.
You can add any Ultra/Wide, single-ended SCSI device in the non-hot-swap shelves, such as a removable
hard disk or a tape backup drive. This table lists supported SCSI devices:
Location
Drive Type
Hot-swap Mass Storage
Shelves
9.1, 18.2 or 36 GB, Ultra-2, 7200 or 10000 rpm drives (up to 35W)
Non-Hot-Swap Shelves
9.1 or 18.2 GB Ultra/Wide or Single-Ended SCSI Drives, 7200 or 10000 rpm
drives
DAT backup systems with SCSI DDS3, or DLT Tape Drives
Accessory Board Guidelines
To install accessory boards, during initial installations, into the I/O board, perform the following procedures.
The I/O board is under the top cover of the LH 6000r and under the left cover of the LH 6000.
l
Use the respective NOS software utility to
◊
Ensure the correct software drivers for the PCI board are loaded
◊
Verify correct operation
◊
Shut down power to hot plug slots
CAUTION
Do not attempt to install or remove non-hot plug PCI boards with the HP NetServer
in any kind of sleep state, or a system crash or hang may occur.
l
Slots 1, 2, 3, and 4 are non-hot plug; slots 5, 6, 7, and 8 are hot plug.
l
For optimal performance, add PCI boards to slots 7 and 8, which at 66 MHz and 64 bit, are the
fastest.
l
Consider the boot priority prior to installing accessory boards, but after configuring the HP
NetServer.
l
Some accessory board outputs may exceed U.S. National Electrical code (NFPA 70) Class 2 or
power source limits and must use appropriate interconnecting cabling in accordance with the
National Electrical Code. (All Hewlett Packard boards comply with Class 2.)
l
You can configure the HP NetServer to boot from a PCI-based DAC inserted into a PCI slot.
Use the Symbios Configuration Utility to select a different PCI slot when scanning for boot
devices.
l
Slots 7 and 8 accept universal boards. Universal boards automatically switch to accept power
from a +5.0 or +3.3 VDC.
Hot Addition and Replacement of Hot Plug PCI Boards
The PCI Hot Plug option is NOS-dependent. To use the Hot Plug option, the PCI board must have a hot plug
compliant driver and a Hot Plug Utility for the respective NOS. The Hot Plug Utility is used to turn power
off/on to the PCI slot, while the HP NetServer continues to operate normally.
Содержание LH6000r - NetServer - 0 MB RAM
Страница 1: ...HP NetServer LH 6000 LH 6000r Service Manual Online Version 1 1 Last Updated May 2000 ...
Страница 22: ...Chapter 1 General Information 16 ...
Страница 39: ...33 3 Parts Information Exploded View Covers Bezel Front Panel 1 1 2 3 15 4 7 9 10 8 11 7 5 13 6 12 14 ...
Страница 41: ...Chapter 3 Parts Information 35 Exploded View Mass Storage 45 44 43 46 47 32 33 35 34 36 37 38 39 40 41 42 40 ...
Страница 43: ...Chapter 3 Parts Information 37 Exploded View Exhaust Fans System Board Assembly See exploded view 65 66 59 ...
Страница 110: ...Chapter 6 Replacing Parts 104 ...