Chapter 5
Troubleshooting
59
6. Plug in the power cords, and turn on power to the HP NetServer. The following message
appears:
The configuration has been cleared. Set the Clear Config switch to the
OFF position before rebooting.
7. Turn off power to the HP NetServer and unplug the power cords.
8. Return switch 5 on the system board to the OFF position.
9. Reconnect cables and power cords to the HP NetServer.
10. Close up the server.
11. Restore HP NetServer to normal operation.
12. Turn on power to the HP NetServer. The error message may be displayed:
0012-34:
Incorrect System Configuration
13. Press the
[F2]
function key and answer
Yes
to save the configuration, then exit the Setup utility.
Password Problems
If you have forgotten the password, your HP NetServer will function normally, but you will not be able to
change the system configuration settings in the Setup utility.
To reset the password, the procedure is the same for the rack-mount and the pedestal HP NetServers once
you gain access to the system board assembly.
1. Log off all users and gracefully shut down the network operating system according to directions
in your NOS documentation.
2. Power down the HP NetServer.
3. Disconnect the power cords and cables and, if necessary, label each one to support re-
assembly.
CAUTION
The power supplies will continue to provide standby current to the NetServer until
the power is disconnected.
4. For both rack-mounted and pedestal models, remove the covers to gain access to the system
board assembly.
NOTE
In the LH 6000r, this assembly is under the right cover; in the LH 6000, it is under
the top cover.
While you can reset the system password in the rack or in the pedestal, it is recommended that you remove
the system board assembly to perform configuration changes.
5. Move switch 6 on the system board (labeled "Clear Password") to the ON position.
6. Plug in the power cords. Turn on power to the HP NetServer and allow it to complete its startup
routine. The old password will be erased.
7. Turn off power to the HP NetServer. Unplug the power cords.
8. Return switch 6 to the OFF position.
9. Reconnect cables and power cords to the HP NetServer.
10. Close up the server.
11. Restore HP NetServer to normal operation.
Содержание LH6000r - NetServer - 0 MB RAM
Страница 1: ...HP NetServer LH 6000 LH 6000r Service Manual Online Version 1 1 Last Updated May 2000 ...
Страница 22: ...Chapter 1 General Information 16 ...
Страница 39: ...33 3 Parts Information Exploded View Covers Bezel Front Panel 1 1 2 3 15 4 7 9 10 8 11 7 5 13 6 12 14 ...
Страница 41: ...Chapter 3 Parts Information 35 Exploded View Mass Storage 45 44 43 46 47 32 33 35 34 36 37 38 39 40 41 42 40 ...
Страница 43: ...Chapter 3 Parts Information 37 Exploded View Exhaust Fans System Board Assembly See exploded view 65 66 59 ...
Страница 110: ...Chapter 6 Replacing Parts 104 ...