Failure effect
Fault stimulus
Short: I/O suspended, possible data loss.
Long: I/O halts with I/O errors, data loss. HBA driver must be reloaded
before failed drives can be recovered, fsck should be run on any failed
drives before remounting.
Server path failure
Short: I/O suspended, possible data loss.
Long: I/O halts with I/O errors, data loss. HBA driver must be reloaded
before failed drives can be recovered, fsck should be run on any failed
drives before remounting.
Storage path failure
IBM AIX
Failure effect
Fault stimulus
Check disk when rebooting. Data loss, data that finished copying survived
Server failure (host power-cycled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Repeated error messages in errpt output. System reboot causes
loss of data on disk. Must crfs disk.
Switch failure (SAN switch disabled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Repeated error messages in errpt output. System reboot causes
loss of data on disk. Must crfs disk.
Controller failure
Short term: Data transfer stops. Possible I/O errors.
Long term: Repeated error messages in errpt output. System reboot causes
loss of data on disk. Must crfs disk.
Controller restart
Short term: Data transfer stops. Possible I/O errors.
Long term: Repeated error messages in errpt output. System reboot causes
loss of data on disk. Must crfs disk.
Server path failure
Short term: Data transfer stops. Possible I/O errors.
Long term: Repeated error messages in errpt output. System reboot causes
loss of data on disk. Must crfs disk.
Storage path failure
VMware
Failure effect
Fault stimulus
OS reboots, automatically checks disks. HSV disks must be manually
checked unless auto mounted by the system.
Server failure (host power-cycled)
Short: I/O suspended, possible data loss.
Long: I/O halts with I/O errors, data loss. HBA driver must be reloaded
before failed drives can be recovered, fsck should be run on any failed
drives before remounting.
Switch failure (SAN switch disabled)
Short term: I/O suspended, possible data loss.
Long term: I/O halts with I/O errors, data loss. Cannot reload driver,
need to reboot system, fsck should be run on any failed disks before
remounting.
Controller failure
Short term: I/O suspended, possible data loss.
Long term: I/O halts with I/O errors, data loss. Cannot reload driver,
need to reboot system, fsck should be run on any failed disks before
remounting.
Controller restart
150
Single path implementation
Содержание EVA P6000
Страница 187: ...German laser notice Italian laser notice Japanese laser notice Laser compliance notices 187 ...
Страница 192: ...Battery replacement notices Dutch battery notice French battery notice 192 Regulatory compliance notices ...
Страница 193: ...German battery notice Italian battery notice Battery replacement notices 193 ...
Страница 194: ...Japanese battery notice Spanish battery notice 194 Regulatory compliance notices ...