Table 23 Error Messages
(continued)
How to correct
Meaning
Status code value
Correct the list such that only one type
of drive is used.
The supplied list of drives contained multiple
drive types.
182
Mixed Drive Types
No corrective action required.
An attempt to enable the OCP Locate LED
failed because the LED is already enabled.
183
Already On
No corrective action required.
An attempt to disable the OCP Locate LED
failed because the LED is already disabled.
184
Already Off
Report the error to product support.
This error is no longer supported.
185
Virtual Disk Info Failed
Report the error to product support.
This error is no longer supported.
186
No Derived Unit for Virtual Disk
Upgrade the source and/or
destination arrays to bring the mix into
compliance.
A data replication configuration is using an
unsupported mix of firmware versions on the
source and destination side.
187
Invalid on DRM Mixed
Configurations
Correct the port parameter and retry
command.
The supplied port number is invalid.
188
Invalid Port Specified
Check the data replication group
parameter and retry.
Specified data replication group not found.
189
Unknown Group
Heal the inoperative condition and
then retry the attach operation.
The empty container being converted to a
snapshot or snapclone is inoperative.
190
Target Object Is Inoperative
Report the error to product support.
A reserved opcode was passed via SCMI
command.
191
Invalid Read16 Operand
Report the error to product support.
A SCMI command was passed with an
invalid destination controller.
192
Invalid Controller
Report the error to product support.
An invalid page code was requested via
SCMI command.
193
Invalid Read16 Special Page
Change asynchronous mode and retry
operation.
Cannot set Failsafe mode while the group
is in asynchronous mode.
194
Cannot Set Failsafe
Case 1: Retry operation using an
empty container.
Case 1: An attach operation was attempted
using a non-empty container.
195
Invalid Logical Disk
Case 2: Retry operation using a mirror
clone.
Case 2: A mirror clone operation was
attempted using a virtual disk that was not
a mirror clone.
Retry the attach, using an empty
container in the same disk group as
the target virtual disk.
An attach operation attempted to attach an
empty container from one disk group to the
target virtual disk from a different disk
group.
196
LDAD Mismatch
Retry with an non-empty virtual disk.
An operation was attempted on an empty
container.
197
Empty Container
Select a different caching policy.
A non-mirrored caching policy was
requested in Active-Active mode.
198
Unsupported for Active-Active
Mode
Retry operation using a RAID type less
than or equal to the RAID type of the
original virtual disk.
A snapshot or snapclone was requested with
a RAID type greater than the original virtual
disk.
199
Incompatible Redundancy
Retry operation using the same RAID
type as the existing snapshots or
snapclones.
A snapshot or snapclone was requested with
a different RAID type different from the
existing snapshots or snapclones.
200
Unsupported Snap Tree
175
Содержание EVA P6000
Страница 187: ...German laser notice Italian laser notice Japanese laser notice Laser compliance notices 187 ...
Страница 192: ...Battery replacement notices Dutch battery notice French battery notice 192 Regulatory compliance notices ...
Страница 193: ...German battery notice Italian battery notice Battery replacement notices 193 ...
Страница 194: ...Japanese battery notice Spanish battery notice 194 Regulatory compliance notices ...