1.
Turn on the SAN switches and wait for all switches to complete the power-on boot process.
It may be necessary to wait several minutes for this to complete.
NOTE:
Before applying power to the rack PDUs, ensure that the power switch on the controller
enclosure is off.
2.
Ensure all power cords are connected to the controller enclosure and disk enclosures. Apply
power to the rack PDUs.
3.
Apply power to the controller enclosure (rear panel on the enclosure). The disk enclosures will
power on automatically. Wait for a solid green status LED on the controller enclosure and disk
enclosures (approximately five minutes).
4.
Wait (up to five minutes) for the array to complete its startup routine.
5.
Apply power to the servers in the SAN with access to the array, start the operating system,
and log in as administrator.
CAUTION:
•
If power is applied to a server and it attempts to boot off of an array that has not been
powered on properly, the server will not start.
•
If a New Hardware Found message appears when you power on a server, cancel the
message and ensure that supported drivers are installed on the server.
6.
Start HP P6000 Command View and verify connection to the storage system. If the storage
system is not visible, click
EVA Storage Network
in the navigation pane, and then click
Discover
in the content pane to discover the array.
NOTE:
If the storage system is still not visible, reboot the management server or management
module to re-establish the communication link.
7.
Check the storage system status using HP P6000 Command View to ensure everything is
operating properly. If any status indicator is not normal, check the log files or contact your
HP-authorized service provider for assistance.
There is a feature in the HP P6000 Control Panel that enables the controllers to boot automatically
when power is applied after a full shutdown. See the HP P6000 Control Panel online help or user
guide for details about setting this feature. To further clarify the use of this feature:
•
If this feature is disabled and you turn on power to the array from the rack power distribution
unit (PDU), only the disk enclosures boot up. With this feature enabled, the controllers will
also boot up, making the entire array ready for use.
•
If, after setting this feature, you remove the management module from its slot and reinsert it
to reset power or you restart the management module from the HP P6000 Control Panel, only
the controllers will automatically boot up after a full shutdown. In this scenario, you must ensure
that the disk enclosures are powered up first; otherwise, the controller boot up process may
be interrupted.
•
After setting this HP P6000 Control Panel feature, if you have to shut down the array, perform
the following steps:
1.
Use HP P6000 Command View to shut down the controllers and disk enclosures.
2.
Turn off power from the rack power distribution unit (PDU).
3.
Turn on power from the rack PDU.
After startup of the management module, the controllers will automatically start.
Restarting the iSCSI or iSCSI/FCoE module
If you determine that the iSCSI or iSCSI/FCoE modules must be rebooted, you can use HP P6000
Command View to restart the modules. Shutting down the iSCSI or iSCSI/FCoE modules through
Storage system shutdown and startup
41
Содержание EVA P6000
Страница 187: ...German laser notice Italian laser notice Japanese laser notice Laser compliance notices 187 ...
Страница 192: ...Battery replacement notices Dutch battery notice French battery notice 192 Regulatory compliance notices ...
Страница 193: ...German battery notice Italian battery notice Battery replacement notices 193 ...
Страница 194: ...Japanese battery notice Spanish battery notice 194 Regulatory compliance notices ...