4.
Enable CHAP for the Microsoft iSCSI Initiator.
a.
Click the
General
tab.
b.
Click
Secret
in the middle of the screen.
c.
Click
Reset
.
d.
Enter the iSCSI or iSCSI/FCoE controller iSCSI Presented Target CHAP secret. For example:
hpstorageworks
.
e.
Click
OK
.
f.
Click
Discovery
.
•
For manually discovering iSCSI target portals:
a.
Click
Add
under
Target Portals
.
b.
Enter the IP address of the iSCSI port of the iSCSI or iSCSI/FCoE controller.
c.
Click
Advanced
.
d.
Select the
CHAP Login Information
check box.
e.
Enter the CHAP secret for the iSCSI or iSCSI/FCoE controller discovered iSCSI
Initiator in the Target Secret box. For example:
CHAPsecret01
.
f.
Select the
Mutual Authentication
check box.
g.
Click
OK
.
h.
Click
OK
and the initiator completes target discovery.
•
Using iSNS for target discovery:
a.
Click
Add
under
iSNS Servers
.
b.
Enter the IP address of the iSNS server.
c.
Click
OK
.
g.
Click
Targets
.
h.
Select the appropriate target for login.
i.
Click
Log On
.
j.
Click
Advanced
.
k.
Select the
CHAP Login Information
check box.
l.
Enter the CHAP secret for the iSCSI or iSCSI/FCoE controller discovered iSCSI Initiator
in the Target Secret box. For example:
CHAPsecret01
.
m. Select the
Mutual Authentication
check box.
n.
Click
OK
.
o.
Click
OK
and the initiator completes normal login.
Enable CHAP for the open-iscsi iSCSI Initiator
To enable CHAP in open-iscsi, you need to edit the
/etc/iscsi/iscsid.conf
file.
1.
Enable CHAP for both Discovery and Normal Session by:
node.session.auth.authmethod = CHAP
node.session.auth.authmethod = CHAP
2.
Setup Username and Password for Initiator and Target for Normal Session. For Example:
# To set a CHAP username and password for initiator
# authentication by the target(s), uncomment the following lines:
#node.session.auth.username = username
#node.session.auth.password = password
node.session.auth.username = iqn.1994-05.com.redhat:fc813cac13.sanergy33
node.session.auth.password = CHAPSecret01
# To set a CHAP username and password for target(s)
# authentication by the initiator, uncomment the following lines:
#node.session.auth.username_in = username_in
node.session.auth.username_in = iqn.2004-09.com.hp.fcgw.mez50.1.01.50014380025da538
#node.session.auth.password_in = password_in
node.session.auth.password_in = hpstorageworks
130 iSCSI or iSCSI/FCoE configuration rules and guidelines
Содержание EVA P6000
Страница 187: ...German laser notice Italian laser notice Japanese laser notice Laser compliance notices 187 ...
Страница 192: ...Battery replacement notices Dutch battery notice French battery notice 192 Regulatory compliance notices ...
Страница 193: ...German battery notice Italian battery notice Battery replacement notices 193 ...
Страница 194: ...Japanese battery notice Spanish battery notice 194 Regulatory compliance notices ...