Chapter 6
HP NetRAID Software
72
Step J. Install NOS and HP NetRAID Drivers
Install Network Operating System (If Necessary)
If the NOS is not already installed on the HP Netserver, install it according to the
instructions you printed in Step I. If you are using Novell NetWare, also see the
Novell NetWare Installation book.
The NOS can be installed on a non-hot-swap drive, on a hot-swap drive not
under HP NetRAID control or on a logical drive under HP NetRAID control.
Install HP NetRAID-1M or 2M Driver
Load the appropriate driver(s) as instructed in the NOS Installation Instructions
that you printed in Step I earlier in this chapter. The driver names are listed in
Table 6-2.
Table 6-2. HP NetRAID Drivers
Network Operating System
HP NetRAID Drivers
Linux
megaraid.o
Microsoft Windows 2000
mraid2k.sys
Microsoft Windows NT
mraidnt.sys
Novell NetWare 4.2 and 5.x
mega4_xx.ham
mega4_xx.ddi
SCO OpenServer
amird
SCO UnixWare
mega