Chapter 8
Upgrading to an HP NetRAID-1M or HP NetRAID-2M Adapter
103
2. Install the new adapter, as described in Step D of Chapter 5, "Installation
and Configuration." If you are installing an HP NetRAID-2M adapter, be
sure to plug in the Battery Backup Unit first (see Figure 8-3, above).
3. Connect all SCSI cables to the new adapter, as described in Step E of
Chapter 5, "Installation and Configuration."
4. Close the HP Netserver panel or replace the HP Netserver cover, plug in
the power cord(s), and turn on power to the HP Netserver.
5. After you see the flashing message "
Firmware Initializing
," you
will see this message:
Configuration of NVRAM and drives mismatch for
Host Adapter X
Run View/Add/Delete Configuration option of
Configuration Utility
Press any key to enter the Configuration Utility.
This message tells you that the configuration information stored in the drives
(the correct configuration) does not match the configuration information stored
in NVRAM on the newly installed HP NetRAID-1M or 2M adapter.
NOTE
If there is more than one HP NetRAID adapter (including any
integrated HP NetRAID controller), the message tells you
which adapter number has the mismatch. Be sure to note
which adapter needs to be reconfigured.
6. Press any key and the HP NetRAID Express Tools utility starts
automatically. You see the Tools Management menu.
7. If you have more than one HP NetRAID-1M or 2M adapter (including any
integrated HP NetRAID controller), do the following to select the adapter
you have just installed:
a. Choose Select Adapter from the Tools Management menu.
b. Choose the adapter with the mismatched configuration.
8. Choose Configure from the Tools Management menu.
9. Choose View/Add/Delete from the Configure menu.
10. Choose Disk, as opposed to NVRAM, from the View/Add/Delete menu.