D2D Appliance
Remote Site 4
D2D Appliance
Remote Site 3
D2D Appliance
Remote Site 2
D2D Appliance
Remote Site 1
Data Center
D2D Appliance
D2D Appliance
Remote Site 6
D2D Appliance
Remote Site 5
Figure 40 HP D2D250x Series Fan IN example
HP D2D400x and 41xx Series
•
Each HP D2D400x Source Appliance can support up to 16 Source Appliances. Each library on
the Target Appliance may be mapped to a maximum of 4 libraries on each Source Appliance. In
other words, up to four Source Libraries may be mapped into a single HP D2D 4000 Target Library.
•
Each HP D2D41xx Source Appliance can support up to 24 Source Appliances. Each library on
the Target Appliance may be mapped to a maximum of 4 libraries on each Source Appliance. In
other words, up to four Source Libraries may be mapped into a single HP D2D 4100 Target Library.
For example: a research establishment has 5 remote sites, and a total of 10 Source Appliances. The
HP D2D400x or 41xx Series Target Appliance at the Data Center can easily support all 10 Source
Appliances.
•
Remote Site 1
and
Remote Site 4
each have one D2D Appliance and are running 4 projects. They
have configured a Source Library for each project on their HP D2D. Each set of 4 libraries can
be mapped to a single library on the Target Appliance at the Data Center. The ability to replicate
slots from up to 4 libraries on Source Appliances into a single Target Library on a Target Appliance
allows for some additional level of data deduplication across the backed up data; for example,
common operating system files.
•
Remote Site 2
has two D2D Appliances, each with two Source Libraries. We can map the slot
mapping collections from those libraries into a single HP D2D 400x Series Target Library. . Source
Appliances 3, 4, 5 and 6 each have one library;
•
Remote Site 3
has two D2D Appliances, one with three Source Libraries and the other with one
Source Library. Again, we can map the slot mapping collections from those libraries into a single
HP D2D 400x Series Target Library.
•
Remote Site 5 has four D2D Appliances, each with one Source Library. We can map the slot
mapping collections from those libraries into a single HP D2D 400x Series Target Library.
Configuring and using replication
80
Содержание D2D
Страница 14: ...14 ...
Страница 18: ...About this guide 18 ...
Страница 30: ...Before you start 30 ...
Страница 52: ...Attaching a physical tape library or tape drive optional 52 ...
Страница 70: ...HP D2D Backup Systems and Fibre Channel 70 ...
Страница 106: ...Configuring and using replication 106 ...
Страница 178: ...Restore processes without replication 178 ...
Страница 196: ...you must create new cartridges Hard disk replacement 196 ...
Страница 204: ...Capacity Upgrade 204 ...
Страница 210: ...210 ...