background image

user guide

hp

 StorageWorks

director product manager

Product Version:  

FW V05.01.00-24/HAFM SW V07.01.00-09

Second Edition June 2003

Part Number:  

AA–RTDUB–TE

This guide provides an introduction and overview of the HP StorageWorks Director 2/64 

Product Manager and Director 2/140 Product Manager. It also explains how to use Product 

Manager features to monitor, manage, and configure a director. Finally it describes how to use 

Director 2/64 and Director 2/140 logs and maintenance features.

Содержание Compaq Presario,Presario 2140

Страница 1: ...r AA RTDUB TE This guide provides an introduction and overview of the HP StorageWorks Director 2 64 Product Manager and Director 2 140 Product Manager It also explains how to use Product Manager features to monitor manage and configure a director Finally it describes how to use Director 2 64 and Director 2 140 logs and maintenance features ...

Страница 2: ... or translated into another language without the prior written consent of Hewlett Packard The information contained in this document is subject to change without notice Microsoft and Windows are U S registered trademarks of Microsoft Corporation Hewlett Packard Company shall not be liable for technical or editorial errors or omissions contained herein The information is provided as is without warr...

Страница 3: ... Stability 18 Getting Help 19 HP Technical Support 19 HP Storage Website 19 HP Authorized Reseller 19 1 Product Manager Overview 21 Managing the StorageWorks Director 2 64 and Director 2 140 22 HAFM Management Menu Options 23 HAFM 23 View Tabs 23 Product Menu 23 Fabrics Menu 23 View Menu 24 Configure Menu 24 Logs Menu 25 Maintenance Menu 25 Help 25 Product Manager 25 View Tabs 26 Product Menu 26 C...

Страница 4: ...uct Manager 34 Window Layout and Function 36 Menu Bar 37 Product Menu 37 Management Style 37 Port 37 FRU 38 Clear System Error Light 38 Enable Unit Beaconing 38 Properties 38 Close 38 Configure Menu 39 Logs 42 Maintenance 43 Help 45 View Tabs 46 Status Bar 47 Hardware View 50 Director Menu 51 Port Card Menu 51 CTP Card Menu 52 Cooling Fan Module 52 SBAR Card Menu 52 Port Card View 52 Port List Vie...

Страница 5: ...70 Status Bar Indicator 71 Monitoring Hardware Operation 71 Obtaining Hardware Information 75 Displaying FRU Information 75 Displaying Director Information 76 Using Menu Options 78 Director Menu 78 Director Properties 78 Enable Unit Beaconing 78 Clear System Error Light 79 IPL Director 79 Setting Director Date and Time 79 Setting Director Online State 81 Port Card Menu 81 Port Menu 82 CTP Card Men...

Страница 6: ...102 Displaying Node Properties 102 Performance View 105 Menu Options 105 Bar Graph Display 106 Port Statistics 106 Statistics Description 107 Traffic Statistics with Receive and Transmit Values 107 Class 2 Statistics 107 Class 3 Statistics 108 Error Statistics 108 Operational Statistics 110 Traffic Statistics with Receive and Transmit Values 110 Troubleshooting Tips 111 Button Functions 111 Port O...

Страница 7: ...pen Systems Management Style 133 Configuring Ports in the FICON Management Style 135 Configuring Port Addresses 136 Parameters 136 Managing Stored Address Configurations 139 Configuring SNMP Trap Message Recipients 141 Configuring Open Systems Management Server 143 Configuring FICON Management Server 143 Configuring Feature Key 143 Configuring Director Date and Time 146 Setting Date and Time Manua...

Страница 8: ...174 Swap Ports 174 Notes 175 Collect Maintenance Data 175 Execute an IPL 176 Set Online State 177 Manage Firmware Versions 178 Enable E Mail Notification 178 Enable Call Home Notification 179 Notes 179 Backup and Restore Configuration 180 Reset Configuration 182 6 Optional Features 185 FICON Management Server 186 Installation 186 Configuring the FICON Management Server 186 Open Systems Management ...

Страница 9: ...et activations 198 Insistent Domain Identification ID 198 Open Trunking 199 Enabling and Configuring Open Trunking 199 Pop Up Menu 202 Use Algorithmic Threshold 202 Threshold 202 Open Trunking Log 202 A Information and Error Messages 205 A StorageWorks Director Product Manager Messages 206 Index 231 Figures 1 Typical network configuration 31 2 HAFM application icon 33 3 Main HAFM window 34 4 Stora...

Страница 10: ...29 Node Properties dialog box 103 30 Performance View 105 31 Configure Identification dialog box 118 32 Configure Switch Parameters dialog box Director 2 64 119 33 Configure Switch Parameters dialog box Director 2 140 119 34 Configure Fabric Parameters dialog box 124 35 Warning dialog box 131 36 Configure Ports dialog box Open Systems management style 133 37 Configure Ports dialog box FICON manage...

Страница 11: ... box 176 60 Backup and Restore Configuration dialog box 180 61 Configure FICON Management Server dialog box 188 62 Configure Open Systems Management Server dialog box 189 63 Switch Binding State Change dialog box 192 64 Switch Binding Membership List dialog box 194 65 Configure Open Trunking dialog box 200 66 Open Trunking Log 203 Tables 1 Document Conventions 15 2 Operating Status Status Bar and ...

Страница 12: ...Contents 12 Director Product Manager User Guide ...

Страница 13: ...40 High Availability Fabric Manager HAFM application The Director 2 64 is a 64 port director while the Director 2 140 is a 140 port director Functions and options available through the Product Manager applications for these products are nearly identical When there are differences this guide will contain notes such as Director 2 64 only or Director 2 140 only About this Guide topics include Overvie...

Страница 14: ...s customer engineers and project managers Related Documentation For a list of corresponding documentation included with this product see the Related Documents section of the HP StorageWorks Director Release Notes For the latest information documentation and firmware releases please visit the HP StorageWorks website http h18006 www1 hp com storage saninfrastructure html For information about Fibre ...

Страница 15: ...nner indicates that failure to follow directions in the warning could result in bodily harm or death Table 1 Document Conventions Element Convention Cross reference links Blue text Figure 1 Key and field names menu items buttons and dialog box titles Bold File names application names and text emphasis Italics User input command and directory names and system responses output and messages Monospace...

Страница 16: ...sence of electrical shock hazards Enclosed area contains no operator serviceable parts WARNING To reduce the risk of personal injury from electrical shock hazards do not open this enclosure Any RJ 45 receptacle marked with these symbols indicates a network interface connection WARNING To reduce the risk of electrical shock fire or damage to the equipment do not plug telephone or telecommunications...

Страница 17: ...l shock remove all power cords to completely disconnect power from the power supplies and systems Any product or assembly marked with these symbols indicates that the component exceeds the recommended weight for one individual to handle safely WARNING To reduce the risk of personal injury or damage to the equipment observe local occupational health and safety requirements and guidelines for manual...

Страница 18: ...quipment be sure that The leveling jacks are extended to the floor The full weight of the rack rests on the leveling jacks In single rack installations the stabilizing feet are attached to the rack In multiple rack installations the racks are coupled Only one rack component is extended at any time A rack may become unstable if more than one rack component is extended for any reason ...

Страница 19: ...tion available before calling Technical support registration number if applicable Product serial numbers Product model names and numbers Applicable error messages Operating system type and revision level Detailed specific questions HP Storage Website The HP website has the latest information on this product as well as the latest drivers Access storage at http www hp com country us eng prodserv sto...

Страница 20: ...About this Guide 20 Director Product Manager User Guide ...

Страница 21: ...r Overview 1 This chapter provides an introduction and overview of the HP StorageWorks Director 2 64 Product Manager and Director 2 140 Product Manager It is intended as a quick reference for using features available through the main Product Manager window ...

Страница 22: ...e online help provides information regarding zoning zone sets and SAN management To launch the web server interface enter the director s IP address as the internet uniform resource locator URL into any standard browser Enter a user name and password at the HAFM Login dialog box The browser then becomes a management console Refer to the web server interface online help for details on use Refer to t...

Страница 23: ...ollowing are lists of options available on the menu bar in the applications References are provided to the correct publication for detailed information on these options HAFM Following are options available through the HAFM For more information refer to Using the HAFM in Chapter 2 of the HP StorageWorks HA Fabric Manager User Guide View Tabs Products Fabrics Product Menu New Open Delete Modify Prop...

Страница 24: ...egrity Binding is installed Fabric Binding active if SANtegrity Binding is installed View Menu User Sessions Zoom In Out Default Fit in View Arrange Icons By name By severity Layout Icons Circular Spring Center in Topology Clear ISL Alerts Clear All ISL Alerts Enable Fly Over Display Configure Menu Users Nicknames Sessions SNMP Agent Activate Zone Set ...

Страница 25: ...Log Product Status Log Fabric Log Maintenance Menu Configure E Mail Test Remote Notification Configure Ethernet Events Configure Enable Call Home Event Notification Help Contents About Product Manager Following are options available through the Product Manager application for your director For more information on these options refer to Configure Menu on page 39 in this manual ...

Страница 26: ...pen Systems FICON Port options available when port is selected Port Properties Node Properties Port Technology Block Port Enable Beaconing Port Diagnostics Channel Wrap FICON Management Style only Swap Ports FICON Management Style only Clear Link Incidents Alert s Reset Port Port Binding Clear Threshold Alert s Display Options Nickname and Worldwide Name ...

Страница 27: ...orts Diagnostics Clear Error System Light Enable Unit Beaconing Properties Close Configure Menu Identification Operating Parameters Switch Fabric Switch Binding Change State active if SANtegrity Binding is installed Edit Membership List active if SANtegrity Binding is installed Ports Addresses FICON Management Style only Active Stored SNMP Agent Management Server Features Date Time Threshold Alert...

Страница 28: ...Audit Log Event Log Hardware Log Link Incident Log Threshold Alerts Log Open Trunking Log active if Open Trunking is installed Maintenance Menu Port Diagnostics Swap Ports FICON Management Style only Data Collection IPL Set Online State Firmware Library Configure Enable E Mail Notification Configure Enable Call Home Backup and Restore Configuration Reset Configuration Help Menu Contents About ...

Страница 29: ... clicking the left or right mouse button you can quickly manage and monitor the director on your network Using the Product Manager you can Back up and restore configuration data Clear the system error indicator Configure extended distance buffering for ports Configure Fibre Channel operating parameters for the director such as BB_Credit R_A_TOV E_D_TOV preferred domain ID insistent domain ID domai...

Страница 30: ...as the port name port number Fibre Channel address operational state type of port and login data Display information on nodes attached to ports Display port performance and statistics Display vital product data for the director such as the system name description contact person location status model number firmware and Engineering Change EC level and manufacturer Enable beaconing for ports and the...

Страница 31: ...tor product icon on the HAFM application s Product View or Topology View Figure 1 illustrates director management components on a public network The figure shows the following elements Figure 1 Typical network configuration 1 Two Director 2 64s 2 HP Ethernet hub 3 HAFM server laptop or rack mount 4 Remote user workstation ...

Страница 32: ... button cancels the operation and closes the dialog box without saving the information you entered Keyboard Navigation Keyboard navigation is an alternative to mouse navigation The Product Manager and HAFM applications support standard keyboard navigation Illustrations Used in This Manual Illustrations of windows and dialog boxes are included for illustrative purposes only These illustrations may ...

Страница 33: ...u double click the HAFM application icon on the desktop as shown in Figure 2 Note that this icon only displays on a remote workstation running the HAFM application remote client software Figure 2 HAFM application icon The HAFM login dialog box displays Go to step 3 If the HAFM application window is open Figure 3 and you need to log in as another user or access a different HAFM server choose Logout...

Страница 34: ... network address of the server if it is not in the list 5 Click Activate or press the Enter key on your keyboard The main HAFM application window displays showing the Product View Figure 3 Main HAFM window Opening the Product Manager To open the Product Manager double click the product icon in the Product View or right click the icon and choose Open The Director icons are shown in Figure 4 1 Menu ...

Страница 35: ...e Figure 4 StorageWorks Director 2 64 and Director 2 140 icons The Product Manager displays showing the default Hardware View Refer to Figure 5 for the Director 2 64 and to Figure 6 for the Director 2 140 Figure 5 StorageWorks Director 2 64 Product Manager window ...

Страница 36: ...ay from the HAFM application window and view both windows on your PC desktop or minimize one or both of them to icons if desired You can have a maximum of four Product Manager windows open concurrently Window Layout and Function The main Product Manager window is divided into four main areas shown in Figure 5 and Figure 6 menu bar view tabs view panel and status bar Use features in these panels to...

Страница 37: ... Enterprise or zSeries server to the director and implementing inband director management through a Fibre Connection FICON channel If director firmware is below the required level and the FICON Management Server feature is enabled the default management style will be FICON The management style cannot be changed to Open Systems with the FICON Management Server feature enabled Port This provides a s...

Страница 38: ...to toggle unit beaconing on or off When the check box has a check mark unit beaconing is on and the amber system error light on the director front bezel blinks to help users locate the actual unit in an equipment room When you click the check box to remove the check mark unit beaconing is disabled and the amber LED goes out You can only enable beaconing if there are no system errors the system err...

Страница 39: ...on to display the Configure Switch Parameters dialog box for setting Fibre Channel operating parameters In this dialog box you can set the preferred domain identification 1 to 31 and also make it insistent if SANtegrity Binding feature is installed You can also enable rerouting delay and domain register for state change notifications RSCNs In addition you can also set the director data speed Direc...

Страница 40: ...t style Use the dialog box to enable extended distance buffering for 10 to 100km link incident LIN alerts and port binding for each port Open Systems management style For each port you can provide a name block or unblock operation configure extended distance buffering for 10 to 100km enable LIN alerts for each port define a type G F and E and enable port binding Note Ports are automatically config...

Страница 41: ...y dialog box Features Displays the Configure Feature Key dialog box Use this dialog box to enter a feature key to enable optional features that you have purchased for the director Date Time Choose this option to display the Configure Date and Time dialog box Use this option to set the current date and time in the director When the Periodic Date Time Synchronization check box is checked in the dial...

Страница 42: ...g the user names and or passwords from their default values to prevent unauthorized access Enable Telnet Choose this option by placing a check mark in the check box to enable telnet access to the director Choose the option again to remove the check mark and disable telnet access When disabled users at remote workstations cannot access the director through telnet to use the Command Line Interface C...

Страница 43: ...put receive throughput or both threshold utilization of traffic capacity minutes the threshold was configured for and the configured time interval for the threshold For more detail on this log refer to Threshold Alert Log on page 171 Open Trunking Log This log provides details on flow rerouting that is occurring through director ports Refer to Open Trunking on page 199 Maintenance The Maintenance ...

Страница 44: ...or 2 64 Service Manual or HP StorageWorks Director 2 140 Service Manual Enable E Mail Notification The Simple Mail Transfer Protocol SMTP server and e mail recipient addresses are configured in the HAFM application not in the Director s Product Manager E mail notification is also initially enabled in the HAFM for all directors managed by the HAFM Note however that the E Mail Notification option on...

Страница 45: ...iguration Choose this option to reset all director configuration data back to the factory defaults A confirmation dialog box displays with a warning upon choosing the option For additional information on using this option refer to Reset Configuration on page 182 WARNING This operation resets all configurations including any optional features that have been installed You will need to reenter any fe...

Страница 46: ...e of detailed information on all FRUs installed in the director A FRU is a hardware component that can be replaced as an assembly if it fails Information includes the FRU name slot position in the chassis relative to identical FRUs in the director operational status active or failed part number and serial number For additional information on this view refer to FRU List View on page 98 Node List Th...

Страница 47: ...symbol displays on the left side of the bar and messages display in the panel to the right of the symbol If a gray square displays in the status bar no Ethernet connection a reason for the status displays in the Status table at the top of the Hardware View Refer to No Link Status on page 70 for details Table 2 Operating Status Status Bar and Director Status Symbol Alert Panel Director Status Table...

Страница 48: ...affected One or more port cards failed but at least one port card is still operational A fan has failed or is not rotating sufficiently One of two CTP cards failed One of two SBAR cards failed Blinking Red Diamond with Yellow Background Not Operational A critical failure prevents the director from performing fundamental switching operations All fans fail Both SBAR cards fail All installed port car...

Страница 49: ...correct Product Type Director status is unknown This occurs if the Ethernet network connection between the HAFM server and the director cannot be established or if the CTP fails Refer to No Link Status on page 70 for details on the status table text Table 2 Operating Status Status Bar and Director Status Continued Symbol Alert Panel Director Status Table Text Meaning ...

Страница 50: ...ent the most degraded status currently reported by any of the director FRUs For example for a port failure indicated by a blinking red and yellow diamond on a port a yellow triangle displays on the status bar to indicate a degraded condition However if a blinking red and yellow diamond displays over both SBAR cards the status bar displays a blinking red and yellow diamond which indicates a failure...

Страница 51: ...om a FRU to display the following options Director Properties Enable Unit Beaconing Clear System Error Light IPL Director Set Director Date and Time Set Director Online State For details on menu options refer to Director Menu on page 78 For details on navigating and monitoring via the Hardware View refer to Chapter 2 Monitoring and Managing the Director Port Card Menu Double click a port card to d...

Страница 52: ...e card For details refer to Fan Module on page 83 Note that these same options are available when you click the fan module and choose the FRU secondary menu from the Product menu on the menu bar SBAR Card Menu Double click an SBAR card to display the FRU Properties dialog box for the card Right click an SBAR card to display the following options For details refer to SBAR Card Menu on page 83 FRU P...

Страница 53: ...s and operation by the status symbols that display next to the port connectors and simulated LED indicators above the connectors Right click the port card to display a menu with Block All Ports Unblock All Ports and Diagnostics options Right click the port connector to display a menu with Port Properties Node Properties Port Technology Block Port Enable Beaconing Port Diagnostics Channel Wrap FICO...

Страница 54: ... box Click Back To Full View to return to the Hardware View Refer to Using the Port Card View on page 84 for detailed information on this view Port List View Choose the Port List View from the View menu A table listing the port number port name port address FICON Management Style only the block unblock configuration operating state port type operating speed and status condition displays in the mai...

Страница 55: ...aconing Port Diagnostics Channel Wrap FICON Management Style only Swap Ports FICON Management Style only Clear Link Incident Alerts Reset Port Port Binding Clear Threshold Alerts Note that these same options also display when you click a port row and choose the Port secondary menu from the Product menu on the menu bar For details on these menu options refer to Port Menu on page 82 For details on n...

Страница 56: ...ge 98 Node List View Choose Node List from the View menu Figure 11 shows an example of the Node List View This view displays a table with information about all node attachments or N_Ports that have logged in to existing F_Ports on the director Only N_Ports display in the Node List View after nodes have logged in to the fabric The columns that display in the table include port number where the node...

Страница 57: ...ode List View by the device s nickname configured through the Define Nickname menu option or the device s WWN Figure 11 Node List View Note that these same options also display when you click a port row and choose the Port secondary menu from the Product menu on the menu bar For details on navigating and monitoring via the Node List View refer to Node List View on page 100 Performance View Choose ...

Страница 58: ...nnected node If the connected node has more than one port this is the WWN of the specific port on the node When a port is functioning as an expansion port E_Port the message is E_Port When a port is not logged into an end device not functioning as an F_Port or to another director not functioning as an E_Port the message is the port s current online state Figure 12 Performance View Right click a ba...

Страница 59: ...ted in the bar graph Values are displayed for transmit and receive traffic class 2 and 3 statistics operational statistics and error categories Click a category in the left side of the statistics area to display only statistics in that category or click All to display values for all categories Click Refresh to update the data with current data from the port Click Clear to clear all of the counters...

Страница 60: ...trator has view rights only while operating in a specific Product Manager application Conversely a Product Manager s product administrator has view rights only while operating in the HAFM application Detailed instructions concerning the assignment of user rights for the HAFM and Product Manager applications display in Chapter 5 of the HP StorageWorks HA Fabric Manager User Guide There are five lev...

Страница 61: ...operation is not authorized Table 3 User Rights for Product Manager Product Manager Rights Product Administrator Operator Maintenance Backup and Restore Configuration X X X Channel Wrap FICON management style X X Clear Audit Log X Clear Event Log X Clear Hardware Log X X Clear LIN Alert X X X Clear LIN Log X Clear System Error Light X Clear Threshold Alerts X Clear Threshold Event Log X Configure ...

Страница 62: ... Trunking X Configure Zoning X Data Collection X Date Time Sync Configuration X X X Enable Call Home Notification X Enable E Mail Notification X Enable Telnet X Enable Web Server X Export Configuration Report X X X FRU Beaconing X FRU Switchover X IPL X X X Manage Firmware X Modify Port Binding X Port Diagnostics X Table 3 User Rights for Product Manager Continued Product Manager Rights Product Ad...

Страница 63: ...eset Statistics Counters Performance View X X Reset Port X X Unit Beaconing X X X View Audit Log X X View Event Log X X X View Firmware X View Hardware Log X X X View LIN Log X X X View Open Trunking Log X X View SNMP X X X View Threshold Alert Log X X X Table 3 User Rights for Product Manager Continued Product Manager Rights Product Administrator Operator Maintenance ...

Страница 64: ...read from the Zip drive The CD RW drive write LED flashes when data is being written to disk A separate application installed on the HAFM server is configured to automatically mirror the contents of the HafmData directory to the Zip drive or CD RW drive when the contents are changed or when you reboot the HAFM server This directory contains all HAFM and Product Manager data so it can be copied bac...

Страница 65: ...server including the following Windows user names and passwords TCP IP network configuration such as IP address gateway address and DNS names The backup application is embedded with the HAFM application A blank backup disk Zip disk or CD RW disk is required for each HAFM server and is included with the HAFM server Restoring Data to the HAFM server To restore data to the HAFM server copy the HafmDa...

Страница 66: ...Product Manager Overview 66 Director Product Manager User Guide ...

Страница 67: ...r describes how to use the features available in the Product Manager main panel to monitor and manage director operation These features include status indicators menu options and dialog boxes available through the Hardware View Port List View FRU List View Node List View and Performance View ...

Страница 68: ...s The Director 2 64 contains up to 16 port cards slot positions 15 through 0 left to right The Director 2 140 contains up to 32 port cards in the front of the unit slot positions 0 31 and up to three additional port cards in the rear slot positions 33 35 The blank slot position 32 relates to ports 128 131 which are internal ports As you move the cursor over each card labels display identifying the...

Страница 69: ...in the Director Status table and the corresponding status symbols that display on the status bar State The State field displays one of the following Offline When the director is OFFLINE all ports are offline The ports cannot accept a login from an attached device or cannot connect to other directors You can configure this state through the Set Online State dialog box Refer to Set Online State on p...

Страница 70: ... connection conditions Link Timeout The network connection that was established between the director and server has been lost Check the IP addresses the Ethernet LAN physical connection between the director and HAFM server IP addresses and other network components Protocol Mismatch The director and the server are not at compatible software release levels Update the HAFM application software versio...

Страница 71: ...ilure that requires immediate attention Monitoring Hardware Operation Determine hardware component operating status and states by the simulated LED indicators and status symbols that display on port cards CTP cards power supplies fan modules and SBAR cards illustrated in the Hardware View Green and amber indicators illuminate on each FRU to indicate either an operational or degraded state respecti...

Страница 72: ...ctor 2 64 Hardware View 1 Port card attention indicator 2 Port card failure indicator 3 CTP card failure indicator 4 Active CTP card indicator 5 Power system error and unit beaconing indicators 6 Power supply failure indicator 7 Cooling fan module failure indicator 8 SBAR card beaconing indicator 9 SBAR failure indicator ...

Страница 73: ...e or service required status A yellow triangle could also indicate that a port is in beaconing state Click the port card to open the Port Card View to examine individual port status Refer to Using the Port Card View on page 84 for details 1 Port card attention indicator 2 Port card failure indicator 3 CTP card failure indicator 4 Active CTP card indicator 5 Power system error and unit beaconing in...

Страница 74: ...P card has become the active card If both CTP cards are operational no LEDs illuminates on the backup card while the green LED illuminates on the active CTP card Power system error and unit beaconing indicators The green and amber indicators on the far right of the front bezel simulate the power and system error LEDs on the actual director bezel Power Indicator The green indicator simulates the po...

Страница 75: ...odule with the amber LED indicator illuminated the module has failed or is rotating insufficiently SBAR card beaconing indicator The yellow triangle status symbol displaying on the SBAR card with the amber LED illuminated indicates that beaconing has been enabled SBAR failure indicator The blinking red and yellow diamond displaying on the SBAR card with the amber LED illuminated indicates a card f...

Страница 76: ... dialog box for a port card when you right click a card and choose FRU Properties from the menu that displays To display a Properties dialog box for an individual port you must be in the Port Card View Refer to Using the Port Card View on page 84 for details Figure 16 Port Card FRU Properties dialog box Displaying Director Information Double click the director illustration away from a hardware com...

Страница 77: ...ame WWN identifier for the director Product type number Product model number Product manufacturer Product serial number Engineering change EC level Firmware level Management Style Open Systems or FICON management style Preferred Domain ID This is set using the Configure Switch Parameters dialog box Active Domain ID The actual domain ID assigned to the director Director Speed Director 2 64 only Thi...

Страница 78: ...ollowing menu options Director Properties Click to display the Director Properties dialog box This dialog box contains the director name description location director data speed and contact person configured through the Configure Identification dialog box Also included is other product information as detailed in Displaying Director Information on page 76 You can also display this dialog box when y...

Страница 79: ...se this option to display the Configure Date and Time dialog box 1 Click to display the Configure Date and Time dialog box The dialog box displays with a check mark the default in the Periodic Date Time Synchronization check box If this field is checked the HAFM server periodically sets the director time to automatically synchronize with the HAFM server time Daylight savings time automatically upd...

Страница 80: ...n option is enabled and then click Sync Now Note If you enable the Periodic Date Time Synchronization feature and click Activate the time will synchronize at the next update period To set the director with a specific date and time make sure that the Periodic Date Time Synchronization field is not selected Refer to Figure 19 Enter the date and time and then click Activate Figure 19 Configure date a...

Страница 81: ... field in the left corner of the Hardware View As the director goes online the word ONLINE displays in the State field in the left corner of the Hardware View When going offline LED indicators on all ports with attached devices stay green but the director sends offline sequences OLS to these devices Port Card Menu Right click a port card in the Hardware View to display the following menu options O...

Страница 82: ...Menu Right click the CTP card in the Hardware View to display a menu with the following options FRU Properties Choose this option to display a FRU Properties dialog box for the CTP card Figure 15 is an example for the power supply module The FRU Properties dialog box includes the FRU name position slot number in the backplane state active backup or failed part number serial number and speed capabi...

Страница 83: ...kplane state active backup or failed part number and serial number SBAR Card Menu Right click an SBAR card in the Hardware View to display a menu with the following options FRU Properties Choose this option to display a FRU Properties dialog box for the card Figure 15 is an example for the power supply module The FRU Properties dialog box includes the FRU name position slot number in the backplane...

Страница 84: ...tors that may display on a port card in the Port Card View Figure 22 Port Card View 1 An amber LED at the top of the card that illuminates if any port fails or blinks if FRU beaconing is enabled 2 A bank of amber and green LEDs above the ports One amber LED and one green LED are associated with each port and indicate port status as follows The green LED illuminates or blinks if there is active tra...

Страница 85: ...the pop up menu When you double click a port s bar graph in the Performance View or right click the bar graph and choosing Port Properties from the menu When you right click a port s row in the Node List View and choose Port Properties from the menu When you click a port port row or port bar graph in the preceding views and choose Port Properties from the secondary Port menu in the Product menu on...

Страница 86: ... page 127 and Using the Port Card View on page 84 for details 10 100 km Configuration Extended distance buffering This can be enabled or disabled for the port through the Configure Ports dialog box Refer to Configuring Ports on page 127 for instructions LIN Alerts Configuration This field indicates whether link incident LIN alerts are enabled or disabled LIN alerts can be configured through the Co...

Страница 87: ... Manual for more information on zoning Build fabric protocol error No principal switch A principal director or switch is not defined for the fabric No response from the attached switch ELP retransmission failure timeout A director or switch with a hardware or link failure attempted to join the fabric and transmitted multiple exchange link protocol ELP frames to another director or switch Because o...

Страница 88: ...as used that was not configured for the attached device in the Product Manager 11 Unresponsive node connected to port Possible causes are 1 a hardware problem on a switch or connected node where ELP frames are not delivered the response is not received or a fabric login FLOGI cannot be received there may be problem in the switch SBAR 2 a faulty or dirty cable connection 3 faulty host bus adapters ...

Страница 89: ...ctions Block All Ports Choose this option to display the Block All Ports dialog box Click Yes to block all ports on the selected card or No to cancel Unblock All Ports Choose this option to display the Unblock All Ports dialog box Click Yes to unblock all ports on the selected card or click No to cancel Diagnostics Choose this option to display the Port Diagnostics dialog box Use this dialog box t...

Страница 90: ...ceiver this would be single mode 9 micron For the shortwave laser LC transceiver this would be multimode 50 micron or 62 5 micron Speed This will be set to either 1 Gbit per second or 1 Gbit 2 Gbit per second Block Port Click to display a check mark and block port transmission If blocked a node attached to the port is prevented from logging into the director or communicating with other devices att...

Страница 91: ...cation Click the check box to remove the check mark and disable channel wrap Swap Ports FICON Management Style only Click this while in FICON management style to display the Swap Ports dialog box Use this dialog box to swap addresses between ports Clear Link Incident Alerts Click this to clear the attention indicator on the Hardware View the Port List View and the Performance View In addition the ...

Страница 92: ...ther the Attached WWN or Detached WWN options With the check box cleared any device can communicate through the port even if a WWN or nickname is specified in the Bound WWN field Attached WWN If a device is logged into the port click this option and the device s WWN displays in the field The device with this WWN or nickname has exclusive communication privileges to the port if Port Binding is enab...

Страница 93: ...ot match the WWN or nickname configured in the field by the WWN option a warning dialog box displays after you activate the configuration This warning box displays a list of all nodes that will be logged off if you continue If you click Continue on the warning box these nodes are logged off and the port only attaches to the device with the WWN or nickname configured in the WWN field An error messa...

Страница 94: ...alled in the director All information is updated automatically The physical port number from 0 63 on the Director 2 64 and 0 127 and 132 143 on the Director 2 140 Note that for the Director 2 140 ports 128 131 are internal ports and not available for external connections Addr FICON Management Style only Displays the logical address of the port The address equals the port number plus 4 For example ...

Страница 95: ...t row right click menus in the Port List View the port bar graph right click menus in the Performance View and the Port secondary menu of the Product menu on the menu bar Blocked states are Blocked Devices communicating with the port are prevented from logging into the director or communicating with other devices attached to director ports A blocked port continuously transmits OLS Unblocked Device...

Страница 96: ... Double click a row to choose it highlight it and display the Port Properties dialog box For an explanation of the fields on the Port Properties dialog box refer to Displaying Port Information on page 85 Menu Options Right click a row to choose it highlight it and display a menu with the following port related action options These are the same menu options that display when you right click a port ...

Страница 97: ...ng the Director 97 Director Product Manager User Guide Reset Port Port Binding Clear Threshold Alerts Note For Node Properties if a node is not logged in a message displays indicating that node information is not available ...

Страница 98: ...on the director All data is dynamic and updates automatically as the software detects changes Figure 27 FRU List View You can display the FRU Properties dialog box for FRU when you click the FRU s row to select it then choose FRU Properties from the FRU submenu on the menu bar s Product menu Information on the FRU List View for each FRU includes FRU An acronym representing the FRU type The meaning...

Страница 99: ...ve single mode MT RJ connector 1 Gigabit GLSR G_Port short wave single mode MT RJ connector 1 Gigabit GXXR G_Port mixed mode MT RJ connector 1 Gigabit GXXL G_Port mixed mode LC connector 1 Gigabit FAN Fan module PWR Power supply Position A number representing the FRU chassis position The chassis slot position for a non redundant FRU is 0 The chassis positions for redundant FRUs are 0 and 1 The cha...

Страница 100: ... includes Port The physical port number from 0 63 on the Director 2 64 and 0 127 and 132 143 on the Director 2 140 Note that for the Director 2 140 ports 128 131 are internal ports and not available for external connections Addr For FICON management style displays the logical port address port number plus 4 For Open Systems management style displays the node s Fibre Channel address Unit Type The f...

Страница 101: ...tly from the device s sense ID when the device attaches to the port during login If the connection is lost to the device the type will display as unspecified since the device is no longer logged into the port When the device logs back in the unit type will update Port WWN The port WWN of the attached node N_Port The 16 digit WWN is a set of unique numbers assigned to the device attached to the por...

Страница 102: ... to 32 characters in the Nickname field and click OK The nickname will display under the Port WWN column instead of the device s WWN Display Options Choose Nickname or Worldwide Name from the submenu Choosing Nickname displays attached devices in the Port WWN column by the nickname configured through the Define Nickname menu option Choosing Worldwide Name displays attached devices in the Port WWN ...

Страница 103: ...is 4 0 4 Port WWN Port World Wide Name of the attached device Port Nickname Nickname for the port WWN Must be configured to display Node WWN Node World Wide Name of the attached device Must be configured to display Node Nickname Nickname for the node WWN Must be configured to display Unit Type Provided by attached device if supported Refer to Node Type under Node List View on page 100 Buffer to Bu...

Страница 104: ...tached to the director port should be two nodes only Type The type of node Model The model of node Serial The Serial number of the node Tag The tag identifier of the node Note The Node Properties option is also available from the menu that displays when you right click a port s row in the Port List View or on a port s bar graph in the Performance View ...

Страница 105: ...u chose Figure 30 Performance View Menu Options Right click any of the port bar graphs to display a pop up menu with the following port related action options These are the same menu options that display when you right click a row in the Port List View or a port in the Port Card View You can also display these options when you click a port port row or bar graph in the preceding views and choose th...

Страница 106: ...ph shows the percentage of link utilization for the port A red arrow marks the highest utilization since the opening of the Performance View If the system detects activity on a port it represents minimal activity with one bar When a port is logged in moving the cursor over its bar graph displays a message with the attached port s WWN If the port is an E_Port the message reads E_Port and if the por...

Страница 107: ...lues panel or click the port s bar graph Clear all counters for all users using Clear Traffic Statistics with Receive and Transmit Values This section describes the types of statistics that display when you click a port s bar graph Link utilization There is a separate value for transmit and receive link utilization The larger of these two values displays on the bar graph The current link utilizati...

Страница 108: ... Statistics The Class 3 Statistics table includes Received Frames The number of Class 3 frames received by this F_Port from its attached N_Port Transmitted Frames The number of Class 3 frames transmitted by this F_Port to its attached N_Port Discarded Frames The number of Class 3 frames discarded including multicast frames with bad D_IDs The director increments this count when it discards a frame ...

Страница 109: ...ion can be due to the attached device performing a reset plugging or unplugging the link bad optics at either end of the cable bad cable or a dirty or poor connection Moving the connection around or replacing cables can isolate the problem Some number of invalid transmission words are expected and acceptable Invalid transmission words within a frame are used to produce the bit error threshold link...

Страница 110: ...ice The director transmits a link reset to initiate the link reset protocol or recover from a link timeout This occurs normally to establish BB_Credit or on any port in order to recover lost BB_Credit The director receives a link reset from an attached device if the device wishes to initiate the link reset or recover from a link timeout Traffic Statistics with Receive and Transmit Values This sect...

Страница 111: ...em is stabilized When looking at the Performance View roughly keep track of the time interval when errors accumulate to judge the presence and severity of a problem Also recognize that there is a link recovery hierarchy implemented in Fibre Channel to handle some level of expected anomalies In general only be concerned with error counts that increment very quickly Button Functions The two buttons ...

Страница 112: ...Card View Port List View or Performance View Inactive Off Off Yellow Triangle The port is inactive Reasons for this state are in the Reason field of the Port Properties dialog box Note that if the port optics have also failed the amber LED will be on Invalid Attachment On Off Yellow Triangle The director port is in an invalid attachment state in either of five cases 1 a loopback plug is connected ...

Страница 113: ...rector port is receiving the Fibre Channel not operational sequence NOS indicating that the attached device is not operational Online On Off None The attached device has successfully connected to the director and is ready to communicate or is in the process of communicating with other attached devices As long as the port remains in the online state the green port LED remains illuminated Note that ...

Страница 114: ...ected to each other Display the Port Properties dialog box to view the segmentation reason Testing Off Blink Yellow Triangle Port is executing an internal loopback test On Blink Yellow Triangle Port is executing an external loopback test Note For any loopback test the amber LED blinks beacons to help users locate the port under test Not Installed Off Off None The port optics are not installed or t...

Страница 115: ...he Link Incident field Or if there are no active incidents None displays The system writes all link incidents to the Link Incident Log You will receive e mail notification of LIN alerts if you enable LIN alerts for a port in the Configure Ports dialog box configure e mail notification through the HAFM application and enable E Mail Notification through the Maintenance menu Note The e mail notificat...

Страница 116: ... which throughput is measured and a time interval during which that throughput value must remain constant When throughput reaches the threshold value and remains constant for the specified time an alert is generated Threshold alerts occur as the following in the Product Manager An attention indicator yellow triangle that displays on the port in the Port Card View An attention indicator yellow tria...

Страница 117: ...ger User Guide 3 Configuring the Director 3 This chapter describes how to use the options that display on the menu when you choose the Configure menu on the menu bar Each of these options is explained in the following sections ...

Страница 118: ...page choose Configure Identification The Configure Identification dialog box displays as shown in Figure 31 Figure 31 Configure Identification dialog box a Type a director name of 24 or fewer alphanumeric characters in the Name field Each director should be configured with a unique name If the director is installed on a public LAN the name should reflect the director s Ethernet network DNS host na...

Страница 119: ...le parameters Verify that the director is set offline For instructions refer to the Setting Director Online State on page 13 Caution Setting the director offline terminates all Fibre Channel connections 2 Choose Configure Operating Parameters Switch Parameters The Configure Switch Parameters dialog box displays Figure 32 displays the switch parameters for the Director 2 64 and Figure 33 displays t...

Страница 120: ...ided to enter a preferred domain ID and a check box is provided to enable this ID as an insistent domain ID Preferred Note To change this value you must first set the director offline Choose Set Online State from the Maintenance menu to display the Set Online State dialog box then click Set Offline Be sure to set the director back online after you change this value Use this field to set the a uniq...

Страница 121: ... ID exists in the fabric both directors E_Ports will segment when they try to join Rerouting Delay Placing a check mark in the check box to the left of the Rerouting Delay option enables rerouting delay This option is only applicable if the configured director is in a multiswitch fabric The default state is enabled Enabling the rerouting delay ensures that frames are delivered in order through the...

Страница 122: ... zone When the Suppress RSCNs on Zone Set Activations check box is selected fabric format RSCNs are not sent for zone changes to the attached devices on the switch Click the check box to remove or add a checkmark This option is enabled check box not selected by default In most cases this option should be enabled so that attached devices can receive notification of zoning changes in the fabric Howe...

Страница 123: ...irmation message to display All FPM ports will be held inactive while the director is configured to 2 Gb sec speed Do you want to continue Management Style Note To change this value you must first set the director offline Choose Set Online State from the Maintenance menu to display the Set Online State dialog box then click Set Offline Be sure to set the director back online after you change this ...

Страница 124: ...ion Setting the director offline terminates all Fibre Channel connections 2 Choose Configure Operating Parameters Fabric Parameters from the Product Manager window The Configure Fabric Parameters dialog box displays as shown in Figure 34 Figure 34 Configure Fabric Parameters dialog box 3 Use information under Fabric Parameters to change settings as required for parameters in this dialog box 4 Afte...

Страница 125: ...condition occurs Resources are allocated to a circuit when errors are detected and are not released for reuse until the time set by the R_A_TOV value expires The default value is 100 tenths 10 seconds Set a value between 10 tenths and 1200 tenths 1 through 120 seconds Note Set the same value for R_A_TOV on all directors and switches in a multiswitch fabric If the value is not the same on all units...

Страница 126: ...nd one to Default the director with the Principal setting that has the lowest WWN becomes the principal director If you have three directors and set two to Default and one to Never Principal the director with the Default setting and the lowest WWN becomes the principal director At least one director in a multiswitch fabric needs to be set as Principal or Default If all of the directors are set to ...

Страница 127: ...t Binding and the WWN binding name Note The Configure Ports dialog box is different for FICON and open systems management style Those options available in open systems management style only are labeled as such The Port Binding feature must be installed before the Port Binding and Bound WWN columns can be used Refer to Configuring Feature Key on page 143 to install the Port Binding feature Port con...

Страница 128: ...n is not enabled the port uses the BB_Credit 1 60 configured through the Operating Parameters dialog box If a device is connected and logged in to the fabric when extended distance is enabled or disabled on the corresponding port the switch will send OLS for 5 ms to force the device to log in again and obtain the new BB_Credit value set for the port LIN Alerts A link incident LIN is a problem dete...

Страница 129: ... E_Ports in Open Systems management style and you install SANtegrity Binding before changing to FICON management style the ports will remain as E_Ports when you change to FICON management style If SANtegrity Binding is not installed setting a director to FICON management style will change all E_ports to G_Ports Port Binding Placing a check mark in the check boxes of this column enables the binding...

Страница 130: ...If the check box in the Port Binding column is not checked any device can connect to the port provided that the port type matches and the check box in the Blocked column is not checked Any WWN or nickname entered in the Bound WWN field is stored When you click Activate if the check box in the Port Binding column is checked and the WWN or nickname in the Port Binding column does not match the devic...

Страница 131: ...ames entered in this column Blocked open systems management style only Block All Ports Places a check mark in all check boxes in the Blocked column and blocks all ports on the switch Unblock All Ports Clears all check boxes in the Blocked column and unblocks all ports on the switch 10 100 km Clear All 10 100 km Clears all check boxes in the column No port will be set for extended distance bufferin...

Страница 132: ... port Unbind All WWNs Removes check marks in all check boxes in this column A device with any WWN can attach to all ports Bind All Ports to Attached WWN Places a check mark in all check boxes in this column and binds each port to the device currently attached to that port The Bound WWN column will display that device s WWN Bind Port to Attached WWN Places a check mark in the check box for the port...

Страница 133: ... attached to that port The Bound WWN column will display that device s WWN Bind Port to Attached WWN Places a check mark in the check box for the port where you clicked to display the menu This binds that port to the device currently attached to that port The Bound WWN column will display that device s WWN Clear All Bound WWNs Clears all WWNs listed in the Bound WWN column Configuring Ports in the...

Страница 134: ... for the port when you click the check box in the LIN Alerts column When a check mark displays LIN alerts are enabled Note The factory default for LIN alerts is enabled 6 Choose a port type when you click in the Type field and selecting from the list 7 Prevent an unspecified device from being connected to the port when you click the check box in the Port Binding column 8 To set the data speed for ...

Страница 135: ...Ports from the Configure menu on the menu bar The Configure Ports dialog box displays as shown in Figure 37 Figure 37 Configure Ports dialog box FICON management style Ports are numbered from 0 63 on the Director 2 64 and 0 127 and 132 143 on the Director 2 140 Note that for the Director 2 140 ports 128 131 are internal ports and not available for external connections 2 Enable or disable extended ...

Страница 136: ...ports that you want to configure 8 Click Activate to activate the changes and close the dialog box 9 If you are finished configuring the switch back up the configuration data For more information refer to Backing Up and Restoring Configuration Data on page 157 Configuring Port Addresses FICON management style only Use this procedure to create and activate port address configurations Parameters Add...

Страница 137: ...ibited symbol and prohibit connection to that cell To remove the prohibit symbol click the cell again Figure 38 Prohibited Port Connection symbol Move your cursor over the squares in the array to display the corresponding address Right click the array to display the following menu options Prohibit row Prohibits connection between all addresses in a row In effect this prohibits connection between a...

Страница 138: ...rrent configuration A warning displays before the action occurs Save As Click to save the current configuration with a name and description The saved configuration will be stored on the HAFM Server and in the Address Configuration Library Refer to Managing Stored Address Configurations on page 139 for information on accessing this library Cancel Click to cancel the configuration settings and close...

Страница 139: ...4 alphanumeric characters allowed including spaces hyphens and underscores 6 Click OK to save changes and to close the Save Address Configuration As dialog box 7 In the Configure Addresses Active dialog box click Activate to activate the configuration or click Cancel to close without activating Note If you click Cancel after saving your configuration will still be added to the library without bein...

Страница 140: ...on dialog box displays provide a name and description for the configuration Names must be between 1 and 8 characters in length Valid characters are uppercase A Z 0 9 hyphen and underscore _ The name may not be CON AUX COMn where n 1 9 LPTn where n 1 9 NUL or PRN Descriptions must be between 0 and 24 characters in length Up to 24 alphanumeric characters are allowed including spaces hyphens and unde...

Страница 141: ...and steps to download MIB variables to your SNMP workstation refer to the HP StorageWorks CLI Reference Guide for Directors and Edge Switches Configure network addresses and community names for up to six SNMP trap recipients An SNMP trap recipient is a network management station that receives messages through SNMP for specific events that occur on the director Define SNMP community names that SNMP...

Страница 142: ...in the box indicates write authorization is enabled When the feature is enabled a management workstation user can change the HAFM server s sysContact sysName and sysLocation SNMP variables c Type the IP address or DNS host name of the trap recipient SNMP management workstation in the associated Trap Recipient field Use 64 or fewer alphanumeric characters Hewlett Packard recommends using the IP add...

Страница 143: ...XxX xxXX xX Note The total number of characters may vary The key is case sensitive and must be entered exactly including the dashes The feature key which is encoded with a director s serial number can only be configured on the director to which it is assigned The serial number used for configuring the feature key is the software readable serial number that can be obtained using the CLI HAFM SNMP o...

Страница 144: ...he director To verify check the serial number of the director through the Switch Properties dialog box and compare it to the serial number listed in the documentation provided with your feature key The feature key is a string of alphanumeric characters with dashes The key is case sensitive so enter the key exactly as printed in the documentation that you received for the feature If an error statin...

Страница 145: ...current features will be replaced with new features That is if there are features shown in the current list that are not shown in the new list then those features will be removed from the director 5 When you are finished configuring the director you can back up the configuration data Note Feature keys are automatically removed when a Director is reset to factory defaults You must then reconfigure ...

Страница 146: ...Figure 44 3 Set director date and time manually or set for periodic updates For specific instructions see the following sections Setting Date and Time Manually on page 146 Synchronizing Date and Time on page 147 Figure 44 Configure Date and Time dialog box Setting Date and Time Manually Use these steps to set the director date and time manually 1 At the Configure Date and Time dialog box click the...

Страница 147: ...e Periodic Date Time Synchronization check box The Date and Time fields are grayed out and not selectable 2 Click Activate to enable synchronization and close the Configure Date and Time dialog box The director date and time synchronize with the HAFM date and time at the next update period at least once daily 3 Click Sync Now to synchronize the director and HAFM immediately The Date and Time Synce...

Страница 148: ...d for the alert Rx Tx or either Active or inactive state of the alert Threshold criteria Percent traffic capacity utilized The percent of the port s throughput capacity achieved by the measured throughput This setting constitutes the threshold value For example a value of 50 means that the port s threshold is reached when throughput is 50 of capacity Time interval during which throughput is measur...

Страница 149: ...ll display in table format showing the name of the alert type of alert Rx Tx or Rx or Tx and alert state inactive or active Figure 45 Configure Threshold Alerts dialog box 2 Click New The New Threshold Alert dialog box displays as shown in Figure 46 Figure 46 New Threshold Alerts dialog box first screen ...

Страница 150: ...ill occur if the threshold set for transmit throughput is reached Rx or Tx Throughput An alert will occur if the threshold set for either receive or transmit throughput is reached 5 Click Next A new screen displays with additional parameters as shown in Figure 47 The name configured for the alert displays at the top of the screen Note Click Previous if you need to return to the previous screen Fig...

Страница 151: ... to 70 560 minutes 9 Click Next A new screen displays for selecting ports for the alerts as shown in Figure 48 Figure 48 New Threshold Alerts dialog box third screen 10 Choose either Port Type or Port List For Port Type choose either E_Ports or F_Ports will cause this alert to generate for all ports configured as E_Ports or F_Ports respectively For Port List you can choose individual ports when yo...

Страница 152: ...rts dialog box displays listing the name type and state of the alert that you just configured 13 At this point the alert is not active To activate the alert choose the alert information that displays in the Configure Threshold Alerts table and click Activate The alert is activated as shown in Figure 50 Figure 50 Configure Threshold Alerts dialog box alert activated ...

Страница 153: ...cation and the time interval for measuring throughput and for alert notification 6 Make appropriate changes then continue through the Modify Threshold screens making changes as necessary until the summary screen displays the alert configuration 7 Perform either of the following steps If you need to change any parameters click Previous or Next to display the desired Modify Threshold screen Click Fi...

Страница 154: ...ert information in the table and click Delete A message displays asking you to confirm the deletion 3 Click Yes The alert is removed from the dialog box Configure Open Trunking This option is only available if the optional Open Trunking feature is installed Choosing this option opens the Configure Open Trunking dialog box For details on enabling Open Trunking and configuring such parameters as con...

Страница 155: ...n Data from the Configure Identification dialog box Operating parameters Data from the Operating Parameters dialog box Port parameters Data from the Configure Ports dialog box SNMP parameters Data from the Configure SNMP dialog box Active zoning configuration This specifies the active zone and zone members if set and whether the default zone is enabled or disabled To export a configuration report ...

Страница 156: ...tically places a check mark in the check box 2 Choose Enable Web Server again to remove the check mark and disable the EWS interface When disabled remote users cannot access the interface For complete procedures on using EWS refer to HP StorageWorks Embedded Web Server User Guide Enabling Telnet Use the following steps to enable Telnet 1 At the Hardware View choose Configure Enable Telnet Choosing...

Страница 157: ...critical data from the HAFM server As long as backup media remains in the backup drive of the HAFM server either an Iomega Zip drive or internal CD RW drive depending on your HAFM server platform data is written to the backup media whenever the directory contents change or you reboot the HAFM server For more information refer to Backing Up and Restoring Product Manager Data on page 64 Note We do n...

Страница 158: ...Configuring the Director 158 Director Product Manager User Guide ...

Страница 159: ...ide 4 Using Logs 4 This chapter describes the StorageWorks Director 2 64 and Director 2 140 logs Access these logs from the logs menu on the menu bar Audit Log Event Log Hardware Log Link Incident Log Threshold Alert Log Open Trunking Log ...

Страница 160: ...e log and displays the Director Product Manager window Export When you click Export on a log window it displays the Save dialog box shown in Figure 52 Click the Home icon to return to the files in your home directory The folders listed in the display area of the Save dialog box after you click the Home icon are those that are stored in your home directory If you choose you may create a folder for ...

Страница 161: ... Expand columns in logs by placing the cursor over the line separating column headings until a double arrow displays then hold down the left mouse button and widen the column as necessary Sorting Entries Sort log entries in columns when you click a column heading A down arrow in the header indicates sorting in descending order An up arrow indicates sorting in ascending order Click once to sort Cli...

Страница 162: ...he change on the director Action User action that caused the configuration change such as offline status port name change or change of address Source Identifies the user making the change through the Director Product Manager and IP or DNS host name address of the remote user s workstation Maintenance Port Change was made by a user connected to the maintenance port HAFM application Change was made ...

Страница 163: ...e user is the Product Manager user name and address is the network address of the workstation remote user workstation or HAFM server SNMP Contains the network address of the SNMP management station Fabric No entry displays Web Server The Identifier column contains user address where user is the web server user name and address is the network address of the web user Fibre Channel Host No entry disp...

Страница 164: ...e Event Log The log provides a maximum of 1000 log entries before it wraps and overwrites the oldest entries For detailed information on event data and problem resolution refer to the HP StorageWorks Director 2 64 Service Manual for the Director 2 64 and the HP StorageWorks Director 2 140 Service Manual for the Director 2 140 Each log entry includes the following Date Time The date and time of the...

Страница 165: ...bit GXXR G_Port mixed mode MT RJ connector 1 Gigabit GSMR G_Port short wave multi mode MT RJ connector 1 Gigabit The chassis slot position for a non redundant FRU is 0 The chassis positions for redundant FRUs are 0 1 and 2 The chassis positions for port cards are 0 through 35 and slot 32 is unavailable Description A short description of the event Severity There are four classifications of severity...

Страница 166: ...cards are 0 through 35 and slot 32 is unavailable Event Data Up to 32 bytes of supplementary information for the event in hexadecimal format For detailed information on event data and problem resolution refer to the event code tables appendix in the HP StorageWorks Director 2 64 Service Manual for the Director 2 64 and the HP StorageWorks Director 2 140 Service Manual for the Director 2 140 ...

Страница 167: ...U The following acronyms may display in this column for the port card GLSL G_Port long wave single mode LC connector 1 Gigabit GSML G_Port short wave multimode LC connector 1 Gigabit GXXL G_Port mixed mode LC connector 1 Gigabit FPM G_Port small form factor optics SFO pluggable FICON port module 1 Gigabit UPM G_Port small form factor optics SFO pluggable universal port module 2 Gigabit Table 6 FRU...

Страница 168: ...ort wave single mode MT RJ connector 1 Gigabit GXXR G_Port mixed mode MT RJ connector 1 Gigabit GSMR G_Port short wave multimode MT RJ connector 1 Gigabit Position Slot position in the chassis relative to identical components installed Action Inserted or removed Part Number Part number of the component Serial Number Serial number of the component ...

Страница 169: ...Link Incident A short description of the incident The following events may cause a link incident to be written to the log Implicit incident The attached node detects a condition that may cause problems on the link Bit error threshold exceeded The number of code violation errors has exceeded threshold Loss of signal or loss of synchronization This occurs if a cable is unplugged from an attached nod...

Страница 170: ...ink reset response primitive sequence was recognized while waiting for the offline sequence For corrective actions in response to these link incident messages refer to the diagnostics chapter in the HP StorageWorks Director 2 64 Service Manual for the Director 2 64 and the HP StorageWorks Director 2 140 Service Manual for the Director 2 140 ...

Страница 171: ...plays details about the alert as configured through the Configure Threshold Alerts option under the Configure menu on the menu bar Figure 57 Threshold Alert Log Date Time Date and time stamp for when the alert occurred Name Name for the alert as configured through the Configure Threshold Alerts dialog box Port Port number where the alert occurred Type The type of alert transmit Tx or receive Rx ...

Страница 172: ... threshold occurs when throughput reaches 25 percent of the port s capacity Alert Time The time that the utilization must exist before an alert is generated This is set through the Configure Threshold Alerts dialog box Interval The time interval during which the throughput is measured and an alert can generate This is set through the Configure Threshold Alerts dialog box Open Trunking Log This log...

Страница 173: ...the Maintenance menu on the menu bar along the top of the Product Manager window The following options are described Port Diagnostics Swap Ports Collect Maintenance Data Execute an IPL Set Online State Manage Firmware Versions Enable E Mail Notification Enable Call Home Notification Backup and Restore Configuration Reset Configuration ...

Страница 174: ...ne port address for another For example if the current address for port 0 is currently 04 and the address for port 1 is currently 05 you can swap so that the address for port 0 has address 05 and port 1 has address 04 To swap ports use the following steps 1 Choose Swap Ports from the Maintenance menu on the menu bar The Swap Ports dialog box displays as shown in Figure 58 Figure 58 Swap Ports dial...

Страница 175: ...is procedure as swapping ports is disruptive to port operation Collect Maintenance Data The Data Collection option enables you to collect maintenance data that can help support personnel diagnose system problems Save the maintenance data as a zip file on a backup disk or other medium with the appropriate capacity and forward it to technical support personnel Note If the Full Volatility feature is ...

Страница 176: ... an IPL on the director use the following steps 1 Choose IPL from the Configure menu on the menu bar The IPL Confirmation dialog box displays as shown in Figure 59 Figure 59 IPL Confirmation dialog box 2 Click Yes Choosing IPL from the Maintenance menu causes Ethernet connection between the director and HAFM server to drop momentarily The following occurs in the Product Manager window As the netwo...

Страница 177: ...led ports are offline The ports transmit an OLS offline sequence and they cannot accept a login for connection from an attached device All ports in the director including E_Ports are placed offline regardless of whether they were blocked or unblocked and the director is removed from a multiswitch fabric Caution Before setting the director offline warn administrators and users currently operating d...

Страница 178: ...able E Mail Notification E mail addresses and the simple mail transfer protocol SMTP server address for e mail notification of director events must be configured through the HAFM application Refer to the HP StorageWorks HA Fabric Manager User Guide for instructions on configuring e mail Note E mail recipients are configured in the HAFM application through the Configure E Mail dialog box A valid SM...

Страница 179: ...s function through the Product Manager for individual directors A choice of two Call Home features is provided when HAFM is installed In legacy HP environments call home notification for directors and switches requires installation of Proactive Service software This service is offered at no additional charge for subsystems covered under an on site warranty or on site storage hardware support contr...

Страница 180: ...rector with the same IP address 1 Choose Backup and Restore Configuration from the Maintenance menu on the menu bar The Backup and Restore Configuration dialog box displays as shown in Figure 60 Figure 60 Backup and Restore Configuration dialog box The Backup and Restore Configuration dialog box consists of a short description of the features performed when you choose Backup or Restore 2 Click Bac...

Страница 181: ... offline No action takes place when you close the dialog box For instructions on setting the director offline or online refer to Set Online State on page 177 4 Click Restore on the Backup and Restore Configuration dialog box to copy the backed up configuration to the nonvolatile random access memory NV RAM on the director If the director is already offline and you click Restore a confirmation dial...

Страница 182: ...ed Web Server interface After resetting the configuration reset LAN addressing to the desired values through the maintenance port or the Embedded Web Server interface If you have enabled the Full Volatility feature through the director s maintenance port this feature will disable when the configuration is reset Note Use of the maintenance port is not covered in this manual For procedures refer to ...

Страница 183: ...64 Service Manual for the Director 2 64 and the HP StorageWorks Director 2 140 Service Manual for the Director 2 140 Table 7 Data Default Values Configuration Description Default Identification Director Name NULL string Director Description Fibre Channel Director Director Contact End User Contact please configure Director Location End User Contact please configure Ports Port Names NULL strings Por...

Страница 184: ...mmunities public 5 NULL strings SNMP Write Authorizations Read only per community Trap Recipient IP Addressees 0 for each UDP Port 162 SNMP Authorization Trap State 5 Zoning Number of Zone Members 0 Number of Zones 0 Number of Zone Sets 0 Zone Names None Zone Sets Names None Zone Members None Default Zone State Enabled Active Zone Set State Disabled Active Zone Set Name NULL string Table 7 Data De...

Страница 185: ...feature keys to be purchased and enabled through the Configure Feature Key dialog box in the product s Product Manager application Features not requiring feature keys themselves but requiring that specific keyed features be enabled before they can be accessed through HAFM or Product Manager applications The following sections are covered in this chapter FICON Management Server Open Systems Managem...

Страница 186: ... installed in order to perform this procedure Switch Clock Alert Mode Click this check box to display a check mark and enable clock alert mode If this is enabled the following occurs when users set the date and time through the Configure Date and Time dialog box Configure menu If you enable Periodic Date Time Synchronization an error message displays indicating that Clock Alert Mode must be cleare...

Страница 187: ...the feature is not enabled you can modify the IPL configuration through the Configure Addresses Active dialog box If the feature is enabled the IPL file is locked to modification through the Configure Addresses Active dialog box Code Page Consider the language required for the port name display that displays on the HAFM Server Language support is provided through character set 697 for all Extended...

Страница 188: ...k Alert Mode check box When a check mark displays the alert mode is enabled 4 Allow or prohibit host control when you click the check box in the Host Control Prohibited field When a check mark displays host control is prohibited 5 Allow or prohibit offline state control when you click the check box in the Programmed offline state control field When a check mark displays programmed control of the o...

Страница 189: ...ort FC CT protocol Installation To install and enable this option choose the Configure Feature Key option under the Product Manager s Configure menu Configuring the Open Systems Management Server Use these procedures to configure the open systems inband management program to function with the switch The optional Open Systems Management Server feature must be installed in order to perform this proc...

Страница 190: ... Area Networks that contain a large and mixed group of fabrics and attached devices Through these features you can allow or prohibit switch attachment to fabrics and device attachment to switches These features are enabled by purchasing a feature key then enabling the key through the Configure Feature Key dialog box SANtegrity Binding features include Fabric Binding Switch Binding Enterprise Fabri...

Страница 191: ...However if Enterprise Fabric Mode is disabled you can disable Fabric Binding Switch Binding or both Switch Binding This feature is managed through the Switch Binding submenu options available on the Product Manager Configure menu Using Switch Binding you can specify devices and switches that can attach to director and switch ports This provides security in environments that include a large number ...

Страница 192: ...Switch Binding Membership list will be maintained when you enable or disable Switch Binding After enabling Switch Binding you prohibit devices and or switches from connecting with director or switch ports by removing them from the Membership List in the Switch Binding Membership List dialog box You allow connections by adding them to the Membership List You can also add detached nodes and switches...

Страница 193: ...ion and removed from the Membership List to prohibit connection Switches are allowed to connect to any E_Port Restrict All Select if you want to restrict connections from specific devices to switch F_Ports and switches to switch E_Ports Device and switch WWNs can be added to the Switch Membership List to allow connection and removed from the Membership List to prohibit connection 4 Click Activate ...

Страница 194: ...h HAFM and you want these to display instead of WWNs in this dialog box click Display Options The Display Options dialog box displays 3 Click Nickname then click OK 4 To prohibit connection to a switch port from a WWN currently in the Membership List click the WWN or nickname in the Membership List then click Remove The WWN or nickname will move to the Node List panel WWNs can only be removed from...

Страница 195: ...ter the appropriate WWN or nickname if configured through HAFM and click OK The WWN or nickname displays in the Switch Membership List 8 Click Activate to enable the changes and close the dialog box Enable Disable and Online State Functions In order for Switch Binding to function specific operating parameters and optional features must be enabled Also there are specific requirements for disabling ...

Страница 196: ...itch is online and Switch Binding is not enabled all nodes and switches attached to the director or switch are automatically added to the Switch Membership List Zoning with Switch Binding Enabled Note that SANtegrity Binding has no effect on existing zoning configurations However note that if a device WWN is in a specific zone but the WWN is not in the Switch Membership List the device cannot log ...

Страница 197: ...destination If there is a change to the fabric topology that creates a new path for example a new switch is added to the fabric frames may be routed over this new path if its hop count is less than a previous path with a minimum hop count This may result in frames being delivered to a destination out of order since frames sent over the new shorter path may arrive ahead of older frames still in rou...

Страница 198: ...zoning changes in the fabric However some HBAs may log out then log back into the fabric when they receive an RSCN thereby disrupting Fibre Channel traffic Consult with your HBA and storage device vendor to determine if disabling this option and thereby enabling RSCN transmission will cause problems with your HBA or storage products Insistent Domain Identification ID This is a parameter in the Con...

Страница 199: ... the most efficient possible use of redundant ISLs between neighboring switches even if these ISLs have different bandwidths Load balancing among the ISLs does not require user configuration other than enabling Open Trunking However if desired you can modify default settings for congestion thresholds per port and low BB_Credit threshold In particular you do not need to manually configure ISLs into...

Страница 200: ... percentage the link is seen as congested and traffic is rerouted if possible to an uncongested link Note that rerouting may not be possible if there are no alternate links available or if alternate links are congested or have no available BB_Credit Note Using default settings for port congestion thresholds should work well in most cases This step is not required a Set the Congestion Threshold usi...

Страница 201: ... enable notification If enabled an unresolved congestion entry is made to the Event Log and an SNMP trap will be generated if trap recipients are configured through the Configure SNMP dialog box An unresolved congestion event occurs when the rerouting algorithm cannot find a path for rerouting data flow and relieving congestion on an ISL Back Pressure Click this check box to display a checkmark an...

Страница 202: ...hese values on the director and close the dialog box Pop Up Menu Right click columns in the Configuration Threshold table to display menu options that globally change values in the column cells Use Algorithmic Threshold Right click in the column to display these options Set all to Default Adds checkmarks to all check boxes in this column and sets all cells of Threshold column to default values Cle...

Страница 203: ... port number on the local switch associated with the flow that was rerouted Target Domain The decimal domain ID associated with the flow that was rerouted Old Exit Port The decimal exit port number on this switch that the flow used to get to the target domain New Exit Port The decimal exit port number on this switch that the flow now uses to get to the target domain ...

Страница 204: ...Optional Features 204 Director Product Manager User Guide ...

Страница 205: ...essages in alphabetical order that display in pop up message boxes from the HP StorageWorks Director Product Manager application If you do not find an error message in this list review the HP StorageWorks HA Fabric Manager User Guide The text of each message is followed by a description and recommended course of action ...

Страница 206: ...erent name that is unique to all saved configurations All FPM ports will be held inactive while the director is configured to 2 Gb sec speed Do you want to continue Occurs when FPM cards are installed in the director and director speed is being set to 2 Gb sec in the Configure Switch Parameters dialog box Replace FPM cards with UPM cards UPM cards operate at 1 and 2 Gb sec or set the director spee...

Страница 207: ... in the Configure Ports dialog box while in FICON management style Cannot disable Switch Binding while Enterprise Fabric Mode is active and the switch is Online User attempted to disable Switch Binding through the Switch Binding Change State dialog box but Enterprise Fabric Mode is enabled You must either disable Enterprise Fabric Mode using the Enterprise Fabric Mode dialog box in the HAFM applic...

Страница 208: ...e menu Cannot have E Ports if Management Style is FICON unless SANtegrity feature is installed Please contact your sales representative Firmware is below the required level and user attempted to change management style from Open Systems to FICON management style with E_Ports configured but SANtegrity Binding is not installed Informational message If firmware is below the required level and you ins...

Страница 209: ...ent SNMP configuration The director SNMP configuration cannot be retrieved by the Product Manager application because the Ethernet link is down or busy Retry the operation later If the condition persists contact the next level of support Cannot retrieve diagnostics results Director diagnostic results cannot be retrieved by the Product Manager application because the Ethernet link is down or busy R...

Страница 210: ...ation because the Ethernet link is down or busy Retry the operation later If the condition persists contact the next level of support Cannot run diagnostics on a port that is failed Port diagnostics loopback tests cannot be performed on a port that has failed any previous diagnostic power on diagnostic online diagnostic or loopback test The amber LED associated with the port illuminates to indicat...

Страница 211: ...rty active save must be disabled for HAFM to save the IPL file Cannot save port configuration The port configuration cannot be saved at the Product Manager application because the Ethernet link is down or busy Retry the operation later If the condition persists contact the next level of support Cannot save SNMP configuration The director SNMP configuration cannot be saved at the Product Manager ap...

Страница 212: ...Channel parameters for the director cannot be set at the Product Manager application because the Ethernet link is down or busy Retry the operation later If the condition persists contact the next level of support Cannot set switch date and time The switch date and time cannot be set at the Product Manager application because the Ethernet link is down or busy Retry the operation later If the condit...

Страница 213: ...an uninstalled port A port swap cannot be performed when the port card is not installed Perform a swap only on a port that is installed Click OK to remove all contents from log This action deletes all contents from the selected log Click OK to delete the log contents or click Cancel to cancel the operation Connection to HAFM server lost Click OK to exit application The HAFM application at a remote...

Страница 214: ...he Ethernet link is down or busy or because the director is busy Retry the operation later If the condition persists contact the next level of support Could not write firmware to flash A firmware version could not be written from the HAFM server to FLASH memory on the director s CTP card Retry the operation again If the condition persists contact the next level of support CUP name and port name ar...

Страница 215: ...rt setting the switch offline or disabling Switch Binding through the Switch Binding Change State dialog box before removing devices from the Switch Membership List Director clock alert mode must be cleared before enabling period synchronization Clock alert mode is enabled through the Configure FICON Management Server dialog box and user is attempting to enable Periodic Date Time Synchronization t...

Страница 216: ...Cancel to cancel the operation Duplicate Community names require identical write authorizations Duplicate community names are entered at the Configure SNMP dialog box and have different write authorizations Delete the duplicate community name or make the write authorizations consistent Enterprise Fabric Mode will be disabled if any of the following parameters are disabled Insistent Domain ID Rerou...

Страница 217: ...e problem Try the file transfer operation again If the problem persists contact the next level of support Field cannot be blank The data field requires an entry and cannot be left blank Enter appropriate information in the Data field Feature not supported The director must be running version 05 00 00 or higher The enterprise operating system E OS version on the hardware product switch or director ...

Страница 218: ...rsists contact the next level of support Firmware file I O error A firmware download operation aborted because a file I O error occurred Retry the operation If the problem persists contact the next level of support Firmware file not found The firmware version is not installed or was deleted from the firmware library at the HAFM server Add the firmware version to the library and retry the operation...

Страница 219: ...er error received from director The director detected an internal file transfer error Retry the operation If the problem persists contact the next level of support Invalid character in field An invalid character was entered in the Data field Remove invalid characters from the entry Invalid configuration name Attempted to save an address configuration name with an invalid name Use up to 24 alphanum...

Страница 220: ...ber must be an integer from 0 through 63 inclusive Verify and enter a valid port number Invalid port number Valid ports are 0 127 132 143 Director 2 140 only Port number must be within the range of ports for the specific director model For this model the valid port numbers are 0 127 and 132 143 Ports 128 131 are not valid because they are internal ports and cannot be connected to external fiber op...

Страница 221: ...nd enter a valid number between 1 through 60 Invalid value for Low BB Credit threshold 1 99 Low BB Credit Threshold field in Configure Open Trunking dialog box must have entries in the range from 1 and 99 This message only displays if the optional OpenTrunking feature is installed Enter a value from 1 to 99 into the Low BB Credit Threshold of the Configure Open Trunking dialog box Invalid value fo...

Страница 222: ... value for R_A_TOV At the Configure Fabric Parameters dialog box the resource allocation time out value R_A_TOV must be an integer from 10 through 1200 inclusive Verify and enter a valid number which must be between 10 through 1200 Invalid value for second 0 59 At the Configure Date and Time dialog box the SS value second must be an integer from 0 through 59 inclusive Verify and enter a valid time...

Страница 223: ...rsists contact the next level of support Log is currently in use Access to the log is denied because the log was opened by another instance of the Product Manager application Retry the operation later If the condition persists contact the next level of support Loopback plug s must be installed on ports being diagnosed Press Next to continue External loopback diagnostics require an optical loopback...

Страница 224: ...ransceivers installed Use a port range that is valid for the ports installed Open Trunking is not installed for this product Please contact your sales representative The Open Trunking feature key has not been enabled This message only displays if the optional Open Trunking feature is installed Enter the feature key into the Configure Feature Key dialog box and enable the key If you require a featu...

Страница 225: ...ding Membership List to determine if the devices should be members Port cannot swap to itself Port addresses entered in the Swap Ports dialog box are the same Ensure that address in the first and second Port Address fields are different Port diagnostics cannot be performed on an inactive port This displays when port diagnostics is run on a port in an inactive state Run the diagnostics on an active...

Страница 226: ...eatures Send firmware failed A firmware download operation failed Retry the firmware download operation If the problem persists contact the next level of support SNMP trap address not defined If an SNMP community name is defined a corresponding SNMP trap recipient address must also be defined Enter a corresponding SNMP trap recipient address Stop diagnostics failed The test is already running Diag...

Страница 227: ...en click OK to continue The data collection process failed An error occurred while performing the data collection procedure Try the data collection procedure again If the problem persists contact the next level of support The data collection process has been aborted The user aborted the data collection procedure Verify the data collection procedure is to be aborted then click OK to continue The de...

Страница 228: ...between the HAFM server and the director is down or unavailable Establish and verify the network connection The firmware file is corrupted A firmware version file is corrupt Contact the next level of support to report the problem The firmware version already exists This firmware version already exists in HAFM server s firmware library Informational message only no action is required The following ...

Страница 229: ...ver is not installed The maximum number of saved address configurations has been reached Delete configurations no longer needed to allow new configurations to be saved This feature has not been installed Please contact your sales representative Indicator that the feature has not been installed on this switch Contact your sales representative to obtain the desired feature This feature key does not ...

Страница 230: ...tional message Unable to change incompatible firmware release The user tried to download a firmware release that is not compatible with the current product configuration Refer to the product release notes or contact the next level of support to report the problem Unable to save data collection file to destination The HAFM server could not save the data collection file to the specified location PC ...

Страница 231: ...y 160 description 42 162 authorized reseller HP 19 B backing up and restoring configuration 180 configuration data 157 backup and restore configuration dialog box 180 backup and restore configuration option 45 bar graph in performance view 106 BB_Credit 102 default value 184 extended distance buffering 128 beaconing enabling for CTP card 82 for FPM card 81 for SBAR card 83 for unit 78 90 port prop...

Страница 232: ...44 procedure 144 configure feature key dialog box procedure 143 configure features menu option 41 configure FICON management server dialog box 188 configure icon 47 configure identification dialog box 39 configure management server 143 configure management style 133 FICON procedure 135 open systems management style procedure 133 configure menu addresses active 138 backup and restore configuration ...

Страница 233: ...me dialog box displaying 102 degraded operation event log 164 delimiter errors 109 diagnostics port FPM card menu 82 port card view menu 89 running 173 dialog boxes 202 address configuration library 139 backup and restore configuration 180 block all ports 82 89 configure addresses active 138 configure date and time 79 configure date and time periodic synchronization 80 configure fabric parameters ...

Страница 234: ... illustration 77 Director Speed director properties dialog box 77 director status table 69 discarded frames 109 displaying port statistics 107 document conventions 15 related documentation 14 domain ID director properties dialog box 77 insistent 121 preferred 120 domain RSCNs 122 enterprise fabric mode 197 E E_D_TOV default value 184 e_d_tov 125 fabric segmentation 125 less than r_a_tov 125 multi ...

Страница 235: ...ature SANtegrity Binding 190 feature key 143 144 configuring 143 Fibre Channel address port properties dialog box 86 fibre channel addresses 120 FICON management style Open Systems 123 FICON management server 37 123 143 186 active saved 187 code page 187 configuration procedure 188 configuring 186 188 host control 186 installing 186 programmed offline state control 187 FICON management style 37 12...

Страница 236: ...ser rights 60 HAFM manager messages 205 HAFM server audit log 162 call home feature 179 configuration backing up and restoring 180 maintenance data 174 hardware failures event log 164 hardware log capacity 160 detailed description 167 general description 43 using 167 hardware view alert conditions 50 component operation monitoring 71 CTP card menu 82 description 46 director information displaying ...

Страница 237: ...199 K keyboard navigation in dialog boxes 32 L languages code page 187 laser LC transceiver 90 LEDs CTP card switchover 83 port card view 84 SBAR card switchover 84 light signal port state 113 LIN alerts configuration port properties dialog box 86 LIN alerts default values 183 link failures 108 link incident causes list of 169 port properties dialog box 86 port state 113 link incident LIN alerts c...

Страница 238: ...nfigurations 139 matrix of port addresses 137 menus configure icon 47 CTP card 52 82 director 51 78 fan module 52 FPM card 51 81 FRU list view 55 hardware view 78 help icon 45 maintenance 43 maintenance menu 43 menu bar description 39 node list view 57 102 performance view 58 105 port 51 82 port card view 52 89 port list 55 port list view 96 product 37 SBAR card 52 83 view icon 39 messages HAFM 20...

Страница 239: ... server 37 143 189 configuring 189 installing 189 open systems management style 37 123 ports configuring procedure 133 open systems mangement style open systems management server 37 Open Trunking feature 199 dialog box 199 dialog box menu 202 enabling and configuring 199 operating parameters default values 184 operating status for the StorageWorks director 2 64 47 operational state port 95 operati...

Страница 240: ...10 100 configuration 86 description 85 displaying 89 96 102 illustration 85 port properties displaying 102 port statistics class 2 statistics 107 class 3 statistics 108 error statistics table 108 traffic statistics 107 110 port technology dialog box displaying 90 port transmission blocking 90 port type 129 port WWN node list view 101 node properties dialog box 103 ports bar graph 58 106 binding 92...

Страница 241: ... list view menu 57 non English language support 187 overview 32 performance view 57 105 performance view menu 58 port list view 54 94 port list view menu 55 port menu 51 product 37 user rights 60 uses list of 29 view icon 39 window layout and function 36 product menu 37 clear system error light 38 close 38 enable unit beaconing 38 FRU 38 port 37 ports 37 properties 38 product view 34 programmed of...

Страница 242: ...efault value 184 speed default 90 speeds UPM cards 123 square gray meaning of 47 statistics values tables 107 statistics ports 59 106 status field 69 status indicator 71 status table 69 StorageWorks director 2 64 alert panel status indicator 71 audit log 162 date and time configuring 146 FRU list view 98 IPL 79 176 link incident log 115 node list view 100 offline state setting 81 operating status ...

Страница 243: ...ox 199 dialog box menu 202 enabling and configuring 199 U UDP port default value 184 unblock all ports dialog box displaying 82 89 unit beaconing enabling 78 United States Canada 00037 code page 187 universal port module cards 123 UPM cards 123 user rights 60 V versions firmware firmware library dialog box 44 managing 178 view icon 39 view menu FRU list 46 hardware 46 node list 46 performance 46 p...

Страница 244: ...Index 244 Director Product Manager User Guide zones number of default value 184 zoning configuration backing up and restoring 181 zoning default values 184 ...

Отзывы: