Chapter 1
Overview
Powering the Server On and Off
43
NOTE
If the power restore feature is set to
Always On
through the iLO MP
PR
command, the server
automatically powers on to the full power state.
Powering On the Server
Power on the server to full power using the following methods if the server is in the standby power state:
•
iLO MP
PC
command
•
Power button
Powering On the Server Using the iLO MP
NOTE
If the power restore feature is set to
Always On
through the iLO MP
PR
command, the server
automatically powers on to the full power state.
To power on the server using the iLO MP, follow these steps:
Step 1.
Plug all power cables into the receptacles on the rear panel of the server.
Step 2.
Initiate a console session, and access the
MP Main Menu
.
Step 3.
Enter
CM
to enable command mode.
Step 4.
Enter
PC
to use the remote power control command.
Step 5.
Enter
ON
to power on the server, and enter
YES
when prompted to confirm the action.
Step 6.
Start the operating system.
Powering On the Server Manually
NOTE
If the power restore feature is set to
Always On
through the iLO MP
PR
command, the server
automatically powers on to the full power state.
To manually power on the server, follow these steps:
Step 1.
Plug all power cables into the receptacles on the rear panel of the server.
Full power
Yes
Yes
Yes
Yes
Off
No
No
No
No
Table 1-17
Power States (Continued)
Power States
Power Cable
Plugged Into
Receptacle?
Power Activated through the
iLO MP
PC
Command; or
Front Panel Power Button
Activated?
Standby
DC Voltage
Applied?
DC Voltage
Applied?
Содержание 9000 rp4410
Страница 54: ...System Specifications Physical and Environmental Specifications Chapter 2 54 ...
Страница 268: ...Chapter 6 Removing and Replacing Components Display Board 268 Figure 6 56 Display Board Removal and Replacement ...
Страница 276: ...Replacement Parts Replacement Parts List Appendix A 276 ...
Страница 284: ...Physical and Environmental Specifications Appendix C 284 ...