Chapter 1
Overview
Powering the Server On and Off
42
Powering the Server On and Off
This section provides information on how to power off and power on the server.
Power States
The server has three power states:
•
Standby power
•
Full power
•
Off
Plug the power cord into the appropriate receptacle on the rear of the server to achieve the standby power
state; the front panel power button is not turned on. Full power occurs when the power cord is plugged into
the appropriate receptacle and either the power is activated through the iLO MP
PC
command, or the power
button is activated. In the off state, the power cords are not plugged in.
Table 1-17 lists the server power states.
Table 1-16
I/O Baseboard LEDs, Buttons, and Sensors
LED/Button
Color
Status
Condition
12V VRM Power LED
Green
On
12V VRM is functioning.
5V VRM Power LED
Green
On
5V VRM is functioning.
3.3V VRM Power LED
Green
On
3.3V VRM is functioning.
iLO MP Heartbeat
Green
Blinking
The iLO MP is functioning correctly.
iLO MP Self Test LED
Amber
On
Off
The iLO MP is executing the internal self test.
The iLO MP passed the internal self test.
BMC Heartbeat
Green
Blinking
The baseboard management controller (BMC) is
functioning correctly.
3.3 VSB Power LED
Green
On
Standby power is available.
iLO MP Soft Reset
Button
N/A
Press
Resets the iLO MP values.
Table 1-17
Power States
Power States
Power Cable
Plugged Into
Receptacle?
Power Activated through the
iLO MP
PC
Command; or
Front Panel Power Button
Activated?
Standby
DC Voltage
Applied?
DC Voltage
Applied?
Standby power
Yes
No
Yes
No
Содержание 9000 rp4410
Страница 54: ...System Specifications Physical and Environmental Specifications Chapter 2 54 ...
Страница 268: ...Chapter 6 Removing and Replacing Components Display Board 268 Figure 6 56 Display Board Removal and Replacement ...
Страница 276: ...Replacement Parts Replacement Parts List Appendix A 276 ...
Страница 284: ...Physical and Environmental Specifications Appendix C 284 ...