8/20q Fibre Channel Switch command line interface guide 299
StopOnError
Stops the test when an error occurs (
True
). Otherwise, the test continues to
completion.
LoopForever
Restarts the test after completion and continues until you cancel it (
True
).
Otherwise, the test ends normally after completion.
Table 73
Switch test parameters (continued)
Parameter
Description
Examples
The following example performs an offline internal test on a switch:
8/20q FC Switch #> admin start
8/20q FC Switch (admin) #>set switch state diagnostics
8/20q FC Switch (admin) #> test switch offline internal
A list of attributes with formatting and current values will follow. Enter a
new value or simply press the ENTER key to accept the default value. If you
wish to terminate this process before reaching the end of the list press 'q'
or 'Q' and the ENTER key to do so.
LoopCount (decimal value, 1-4294967295) [100 ]
FrameSize (decimal value, 40-2148) [256 ]
DataPattern (32-bit hex value or 'Default') [Default]
StopOnError (True / False) [True ]
LoopForever (True / False) [False ]
Do you want to start the test? (y/n) [n] y
See also
test cancel
, page 293
test status
, page 296
test switch
, page 298
Содержание 8/20q
Страница 14: ...14 About this guide ...
Страница 20: ...20 Command line interface usage ...
Страница 24: ...24 User account configuration ...
Страница 38: ...38 Network configuration ...
Страница 90: ...90 Connection security configuration ...
Страница 100: ...100 Device security configuration ...
Страница 104: ...104 RADIUS server configuration ...
Страница 110: ...110 Event log configuration ...
Страница 130: ...130 Simple Network Management Protocol configuration ...
Страница 322: ...322 Command reference ...
Страница 332: ...332 Index ...