Configuring the switch
197
RMON History Configuration
To display the following form, go to the RMON History Groups Configuration form. Select a History
Group, or open the History folder and click
Add History Group.
The following table describes the History Group Configuration controls:
Table 130
History Group Configuration controls
Control Description
History Group ID (1-65535) Configures a numeric identifier for the selected History index.
MIB Object ID
Configures the interface MIB Object Identifier. The IFOID must correspond to the
standard interface OID, as follows:
1.3.6.1.2.1.2.2.1.1.x
where
x
is the ifIndex
The interface OID can have a maximum of 127 characters.
Number of Buckets
Requested (1-65535)
Configures the number of requested buckets, which is the number of data slots into
which data is to be saved.
The range is from 1 to 65535. The default is 30.
NOTE:
The maximum number of buckets that can be granted is 50.
Polling Interval (1-3600)
Configures the time interval over which the data is sampled for each bucket.
The range is from 1 to 3600 seconds. The default value is 1800 seconds.
Owner
Enter a text string that identifies the person or entity that uses this History Group.
The owner can have a maximum of 127 characters.