HP StorageWorks 1000 Modular Smart Array installation guide
93
IMPORTANT:
In multipath configurations:
•
Verify that both HBAs in each server have been granted access to the storage.
•
In active/active configurations, manually assign a preferred path (controller ownership) for each
LUN. By default, MSA firmware initially assigns ownership of all LUNs to the controller in slot
one (front-right) of the MSA. Then, based on access patterns and I/O load, the firmware
automatically re-assigns ownership of the LUN between the controllers to balance the load. If
your environment controls load balancing from the host, you must manually assign the preferred
path for each LUN.
Perform these tasks using your chosen configuration utility. Refer to the appropriate user
documentation for procedural instructions.
Go to
Table 13
: ”
Hard drive information
” on page 112 and
Table 14
: ”
Array (LUN) information
” on
page 116 to record information about your storage.
Содержание 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive
Страница 58: ...Installation procedures All deployments 58 ...
Страница 64: ...Configuration procedures Windows environments 64 ...
Страница 70: ...Configuration procedures Linux environments 70 ...
Страница 76: ...Configuration procedures HP UX environments 76 ...
Страница 82: ...Configuration procedures OpenVMS environments 82 ...
Страница 94: ...Configuration procedures Other environments 94 ...
Страница 98: ...Powering off and powering on the MSA 98 ...
Страница 104: ...Electrostatic discharge 104 ...
Страница 123: ...HP StorageWorks 1000 Modular Smart Array installation guide 123 prerequisites for the MSA 59 updating MSA firmware 62 ...