HP StorageWorks 1000 Modular Smart Array installation guide
85
•
Prepare the server:
NOTE:
Multipathing software is native to VMware; therefore, there is no need to install any
additional multipathing software.
• VMware ESX Server installs directly on the server hardware. It virtualizes server storage and
networking, allowing multiple applications to run in virtual machines on the same physical
servers. ESX Server partitions a physical server into multiple secure and portable virtual
machines that can run side by side on the same physical server.
• Configure the VMware ESX 2.5.X Server:
1.
Open the management interface and select the
Options
tab. Then, select
Advanced Settings...
2.
Scroll down to Disk.MaxLUN.
The default value is 8. Change the value to meet your configuration needs. If the
value is less than the number of LUNs you have presented, you will not see all of your
LUNs. The maximum value for this field is 256.