114
Group Status : -
NOTE:
If you perform the
display mpls te tunnel-interface
command immediately after an FRR protection switch,
you are likely to see two CR-LSPs in up state are present. This is normal because the make-before-break
mechanism of FRR introduces a delay before removing the old LSP after a new LSP is created.
Perform the
display mpls lsp verbose
command on Switch B. You can see that the bypass tunnel is
in use.
[SwitchB] display mpls lsp verbose
------------------------------------------------------------------
LSP Information: RSVP LSP
------------------------------------------------------------------
No : 1
IngressLsrID : 1.1.1.1
LocalLspID : 1
Tunnel-Interface : Tunnel4
Fec : 4.4.4.4/32
Nexthop : 3.1.1.2
In-Label : 1024
Out-Label : 1024
In-Interface : Vlan-interface1
Out-Interface : Vlan-interface2
LspIndex : 4097
Tunnel ID : 0x22001
LsrType : Transit
Bypass In Use : In Use
BypassTunnel : Tunnel Index[Tunnel5], InnerLabel[1024]
Mpls-Mtu : 1500
No : 2
IngressLsrID : 2.2.2.2
LocalLspID : 1
Tunnel-Interface : Tunnel5
Fec : 3.3.3.3/32
Nexthop : 3.2.1.2
In-Label : NULL
Out-Label : 1024
In-Interface : ----------
Out-Interface : Vlan-interface4
LspIndex : 4098
Tunnel ID : 0x22002
LsrType : Ingress
Bypass In Use : Not Exists
BypassTunnel : Tunnel Index[---]
Mpls-Mtu : 1500
# Set the FRR polling timer to five seconds on PLR.
[SwitchB] mpls