64
4 214 153 / 00
HEATING SYSTEM CONTROL
5.12.4 Power station
(Main menu / Energy control)
6
4
5
1
2
7
3
No.
Designation
Function
1
Heating circuits
Selection of the heating circuit to be edited.
2
Circuit selection
There can be several circuits in the selected heating circuit. If the system
contains more than one circuit, this is indicated by the white, active hori-
zontal arrows ( ). If there is only one heating or hot water circuit, the
arrows are greyed out.
3
Eco-Comfort slider
If the slider is moved to
“Eco”
, the heating control is influenced by the
weather forecast to the greatest possible extent.
If the slider is moved to
“Comfort”
, the weather forecast is not consid-
ered.
If the forecast is not received, it may not be possible for the re-
quired room temperature to be maintained. However, the pos-
sible energy saving is at its greatest in this position.
4
Position in the menu
Name of the currently selected menu item
5
Time of day
Displays the current time.
6
Help
No function is available at present
7
Back
Used as a button ( ) for returning to the main menu.