81
4 214 153 / 00
MAINTENANCE
NOTICE
When filled right to the rim, the ash box can
weigh up to 40 kg. Use the extendible handle
only to pull out the ash box, in order to pre-
vent damage.
2
1
4
3
Fig. 06
5. To empty, open the two top spring clips (3, Fig. 06)
and remove the lid (4, Fig. 06).
6. Reattach the lid after emptying. Ensure that the lid
closes tight (check seal)!
8.1.2 Attaching the ash box
1. Open the cover (Fig. 05) on the back.
2. Remove the excess ash from the ash discharge
screw. If you use a vacuum cleaner, be careful not to
draw in any ember particles, as otherwise, your vacu-
um cleaner may be damaged.
3. Slide the ash box onto the system and position it with
the help of the stop on the top right (2, Fig. 04). The
system detects that the ash box has been replaced
and switches on again.
4. Lock the ash box in position by closing the two bottom
5. Acknowledge the message: according to description
on the display (Press "Acknowledge").
8.2
Annual maintenance (major maintenance)
The TopTronic E control is equipped with a “cleaning in-
dicator”. This means after a particular number of pellets
has been burned, an alarm message appears on the dis-
play (orange warning triangle).
The alarm message can be called up by touching the
warning triangle, see chapter 6.1
The annual maintenance must be performed
by a heating specialist.
Depending on the boiler output, major maintenance must
be performed at the latest after the following amounts of
pellets have been consumed (even if this is the case be-
fore one year has expired): BioLyt (8) after 3 tonnes, Bio-
Lyt (13) after 5 tonnes, BioLyt (15) after 6 tonnes, BioLyt
(23,25) after 8 tonnes, BioLyt (31) after 10 tonnes, BioLyt
(36,43) after 12 tonnes.
Some of the following tasks may need to be performed
earlier, depending on the pellet quality and the boiler ope-
rating mode.
8.2.1 Preparation
1. Switch the boiler off with the blocking switch (see 4.1
2. Allow the boiler to cool down for at least 30 minutes.
3. Pull out the ash box.
4. Tip: The front door can be easily unhooked at the two
hinges; this allows easier access to the burner and
the combustion chamber for maintenance purposes.
WARNING
Danger: electrical voltage! The boiler must
be disconnected from the mains before per-
forming annual maintenance (all-pole main
switch, main fuse or in Switzerland the mains
plug).
8.2.2 Clean the flue gas collector
1.
Open the cover of the flue gas collector:
- Release four screws (1, Fig. 07).
- Grip the cover by the handles (1a), turn it slightly in
anti-clockwise direction and lift off.
1
1a
1a
Fig. 07
Содержание BioLyt 13