56
4 214 153 / 00
HEATING SYSTEM CONTROL
5.11.4 Day programs / switching cycles for hot water
You can adapt the hot water day programs and switching
cycles to your individual requirements and, in this way,
control the water heating specifically for the required time
period and hot water temperature if you use the hot water
on a regular basis, for example.
• The hot water day programs/switching cy-
cles are independent from the heating cir-
cuit day programs (5.10 page 43).
•
The preset day programs with defined
switching cycles can be adapted and re-
named.
• The switching cycles of a day program are
only active if the corresponding week pro-
gram is selected as the basic program.
• A maximum of six switching cycles are pos-
sible for each day program.
5.11.5 Default settings for day programs / switching
cycles – hot water
In the factory setting, the names and the switching cycles
of the hot water day programs are predefined as with the
heating circuits. Two of these standard day programs (all
day and early & late) are assigned to both week programs
Week 1
and
Week 2
. If you adapt these two day pro-
grams to your individual requirements, you need to con-
sider that both week programs are also changed (5.11.2
page 55). You can edit the default settings listed below
as you require (5.12.6 page 66), rename them at any
time (5.12.6 page 66) and reset to the default settings
Default settings for day programs – hot water:
Day programs
Switching cycle / temperature
Example
All day
from
to
°C
00:00
06:00
45
05:30
22:00
50
22:00
00:00
45
I work at home and I am present all day.
Early & late
from
to
°C
00:00
05:30
45
05:30
08:00
50
08:00
15:30
45
15:30
22:00
50
22:00
00:00
45
I go to work at 08:00 hours in the morn-
ing and I do not return home until 17:00
hours in the evening.
Only evening
from
to
°C
00:00
15:30
45
15:30
22:00
50
22:00
00:00
45
I do not need any hot water in the morn-
ing before I set off to work. I get back
home at 17:00 hours in the evening.
All day legio
from
to
°C
00:00
05:30
45
05:30
15:30
50
15:30
16:30
60
16:30
22:00
50
22:00
00:00
45
I work at home and I am present all day.
In addition, the legionella function is ac-
Содержание BioLyt 13
Страница 87: ...87 4 214 153 00 NOTES...