Bela08+16I3
Hoval BelariaSRM
4P330420-1A – 2012.11
Installation manual
11
4 211 846 / 00 – 11/12
4 Configuration
4.2
Basic configuration
4.2.1 Quick wizard: Language / time and date
4.2.2 Quick wizard: Standard
Backup heater configuration
Space heating/cooling settings
4.2.3 Quick wizard: Options
Domestic hot water settings
#
Code
Description
[A.1]
N/A
Language
[1]
N/A
Time and date
#
Code
Description
[A.2.1.5]
[5-0D]
Backup heater type:
1 (1P,(1/1+2)): 6 kW 1~ 230 V (*9W)
3 (3P,(1/1+2)): 6 kW 3~ 230 V (*9W)
4 (3PN,(1/2)): 6 kW 3N~ 400 V
(*9W)
5 (3PN,(1/1+2)): 9 kW 3N~ 400 V
(*9W)
#
Code
Description
[A.2.1.7]
[C-07]
Unit temperature control:
0 (LWT control): Unit operation is
decided based on the leaving water
temperature.
1 (Ext RT control): Unit operation is
decided by the external thermostat.
2 (RT control): Unit operation is
decided based on the ambient
temperature of the user interface.
[A.2.1.B]
N/A
Only if there are 2 user interfaces:
User interface location:
At unit
In room
[A.2.1.8]
[7-02]
Number of water temperature zones:
0 (1 LWT zone): Main
1 (2 LWT zones): Main + additional
[A.2.1.9]
[F-0D]
Pump operation:
0 (Continuous): Continuous pump
operation, regardless of thermo ON
or OFF condition.
1 (Sample): When thermo OFF
condition occurs, the pump runs
every 5 minutes and the water
temperature is checked. If the water
temperature is below target, unit
operation can start.
2 (Request): Pump operation based
on request. Example: Using a room
thermostat and thermostat creates
thermo ON/OFF condition.
#
Code
Description
[A.2.2.1]
[E-05]
Domestic hot water tank:
0 (No): NOT installed
1 (Yes): Installed
[A.2.2.3]
[E-07]
Tank booster heater:
0 (Horizontal BSH): Installed at side
of the tank
1 (Backup heater): NOT installed
2: N/A
3: N/A
[A.2.2.A]
[D-02]
Domestic hot water pump:
0 (No): NOT installed
1 (Secondary rtrn): Installed for
instant hot water
2 (Disinf. shunt): Installed for
disinfection
See also illustrations below.
Domestic hot water pump installed for…
Instant hot water
Disinfection
a
Indoor unit
b
Tank
c
Domestic hot water pump
d
Heater element
e
Non-return valve
f
Shower
g
Cold water
c
f
b
a
g
c
b
a
d
f
e
g
4P330420-1A - 2012.11_offset.book Page 11 Thursday, December 13, 2012 3:35 PM