3 Installation
6
Close the drain and fill valve.
7
Disconnect the water supply hose from the drain and fill valve.
3.4.3 To fill the domestic hot water tank
For installation instructions, see the installation manual of the
domestic hot water tank.
3.4.4 To insulate the water piping
The piping in the complete water circuit must be insulated to prevent
condensation during cooling operation and reduction of the heating
and cooling capacity.
If the temperature is higher than 30°C and the humidity is higher than
RH 80%, the thickness of the sealing materials should be at least
20 mm to prevent condensation on the surface of the sealing.
3.5
Connecting the electrical wiring
3.5.1 About electrical compliance
See "3.5.4 To connect the backup heater power supply" on page 6.
3.5.2 To connect the electrical wiring on the
indoor unit
1
To open the indoor unit, see To open the indoor unit.
2
Wiring should enter the unit from the bottom.
3
Routing of the wiring inside the unit should be as follows:
For Bela08:
For BelariaSR16:
NOTICE
Air in the water circuit can cause malfunctioning of the
backup heater. During filling, it may not be possible to
remove all the air from the circuit. Remaining air will be
removed through the automatic air purge valves during
the initial operating hours of the system. Additional filling
with water afterwards may be required.
To purge the system, use the special function as
described in the chapter Commissioning. This function
should be used to purge the heat exchanger coil of the
domestic hot water tank.
DANGER: RISK OF ELECTROCUTION
WARNING
Always use multicore cable for power supply cables.
INFORMATION
When installing field supply or option cables, foresee
sufficient cable length. This will make it possible to
remove/reposition the switch box and gain acces to other
components during service.
a
a
b
c
a
b
c
a
c
b
a
c
c
c
b
Routing
Possible cables (depending on unit type and installed options)
a
Low voltage
User interface
Domestic hot water tank thermistor (option)
Power consumption digital inputs (field supply)
Outdoor ambient temperature sensor (option)
Indoor ambient temperature sensor (option)
Electrical meters (field supply)
b
High voltage power supply
Interconnection cable
Normal kWh rate power supply
Preferential kWh rate power supply
Power supply for backup heater
Power supply for bottom plate heater (option)
Power supply for booster heater (to indoor unit)
Power supply for booster heater and thermal protection (from indoor unit)
c
High voltage control signal
Preferential power supply contact
Heat pump convector (option)
Room thermostat (option)
3-way valve
Shut-off valve (field supply)
Domestic hot water pump (field supply)
Alarm output
Changeover to external heat source control
Space heat/cool operation control