TOUCH USER MANUAL 43
TROUBLESHOOTING
Error Code
Problem
Possible solution
42
SW defect
A software defect has been detected
during operation. The steam generator
was activated by mistake. Contact
HOUNÖ technical support.
45
24V failure
There is no 24V AC. The main contactor
output is not working. Check fuse F1.
50 / 60*
Pressure switch active
The pressure switch or gas valve input
is active when the fan is not running.
Try to restart oven. Contact authorized
service personnel.
51 / 61*
Pressure switch failure
The pressure switch is not active when
the gas-air control unit is running. Try
to restart oven. Contact authorized
service personnel.
52 / 62*
Gas valve failure
The automatic gas burner control has
failed to switch on the gas valve. Try
to restart oven. Contact authorized
service personnel.
53 / 63*
Fan RPM
The gas-air control unit does not
revolve while the pressure switch is
active. Try to restart oven. Contact
authorized service personnel.
54 / 64*
Fan error
The gas-air control unit does not run
at the correct RPM just before ignition.
Try to restart oven. Contact authorized
service personnel.
55 / 65*
Ignition failure
Ignition failed. Try to restart oven.
Contact authorized service personnel.
56 / 66*
Gas failure
The flame has failed to occur after 3
attempts to ignite. Try to restart oven.
Contact authorized service personnel.
57 / 67*
Stop during operation
There was a gas failure during
operation. Try to restart oven. Contact
authorized service personnel.
*Error codes 60-67 relates to gas fan 2 for gas ovens 1.20 roll-in and 2.20 roll-in. Try to
restart oven. Contact authorized service personnel.