32 of 40
Service Manual UK
Indesit
Company
English
K.
Water Softener
1.
Remove air-break as in J).
2.
Unscrew salt cap and ring nut of water
softener.
3.
Remove base access panel as in D).
4.
Release hose from sump to water
softener.
5.
Disconnect salt reading module and
regeneration valve wiring and release the
water softener from its fixing clip.
6.
Rotate the water softener outwards from
regeneration valve end and lift up to allow
filler neck to be removed from the tank.
L.
Sump
1.
Remove filters and lower spray arm.
2.
Remove 2 fixing screws and detach upper wash arm inlet pipe from sump.
3.
Remove 4 screws from sump ring and remove
4.
Follow steps D), E), F) and G).
5.
Remove wiring to turbidity sensor, detach the NTC and remove the sump.
M. Turbidity Sensor
1.
Facing the front of machine remove r/h side panel as in A).
2.
Ease clips away from unit and withdraw sensor.
3.
Disconnect wiring.
N.
Dispenser
The dispenser cannot currently be replaced as an individual part.
It is part of the inner door panel.