45
2. Sanitizing Procedure - Following Cleaning Procedure
1) Dilute a 5.25% sodium hypochlorite solution (chlorine bleach) with warm water (add
1.25 fl. oz. (37 ml) to 2.5 gal. (9.5 l) of water).
2) Remove the insulation panel.
3) Pour the sanitizing solution into the water tank.
4) Replace the insulation panel and the front panel in their correct positions.
Note: Make sure the control switch is in the "WASH" position and the cleaning valve is
open.
5) Turn on the power supply to start the sanitizing process.
6) Turn off the power supply after 15 minutes.
7) Remove the front panel.
8) Remove the insulation panel. Remove cube guide B, then remove cube guide A.
Remove the overflow cap, overflow pipe, and water shield.
9) Remove the drain plug. Allow the water tank to drain, then replace the drain plug in its
correct position.
10) Replace the water shield, overflow pipe, overflow cap, cube guide A, cube guide B, and
insulation panel in their correct positions.
11) Repeat steps 17 through 30 in "1. Cleaning Procedure" two times to rinse thoroughly.
12) Close the cleaning valve.
13) Move the control switch to the "ICE" position.
14) Replace the front panel in its correct position.
15) Clean the dispenser unit/storage bin liner using a neutral cleaner. Rinse thoroughly after
cleaning.
16) Turn on the power supply to start the automatic icemaking process.