Freeze Up - Possible Cause
6. Float Switch
See "IV.D. Float Switch Check
and Cleaning"
a) Dirty, sticking.
b) Defective.
7. Refrigerant Charge
a) Low.
8. Control Board
See "II.C.2. Controls and
Adjustments" and "IV.B. Control
Board Check"
a) Harvest timer (S4 dip switch 1 & 2) set too short.
b) Harvest pump timer (S4 dip switch 3 & 4) not in factory default
position.
c) Defective.
9. Bin Control
See "IV.C. Bin Control Check and
Cleaning"
a) Actuator does not move freely.
10. Thermistor
See "IV.E. Thermistor Check"
a) Loose, disconnected, or defective.
11. Expansion Valve (TXV)
a) Defective.
12. Hot Gas Valves (KMS & SRK)
a) Closed.
13. Liquid Line Valves (KMS & SRK) a) Open.
14. Drain Valve Relay
a) Bad contacts. Open coil. Not allowing pump motor operation during
last 50 seconds of harvest.
Freeze Cycle
1. Evaporator
a) Scaled up.
b) Damaged.
2. Spray Tubes and/or Spray
Guides
a) Dirty.
b) Out of position.
3. Refrigerant charge
a) Low.
4. Control Board
See "IV.B. Control Board Check"
a) Freeze timer set incorrectly.
b) Defective.
5. Inlet Water Valve
a) Leaking by.
6. Float Switch
See "IV.D. Float Switch Check
and Cleaning"
a) Float does not move freely.
b) Defective.
7. Pump Motor
a) RPM too slow.
8. Expansion Valve (TXV)
a) Bulb loose or Defective.
9. Headmaster (C.P.R.)
a) Defective.