(iv) After Step (iii), de-energize the unit and confirm that the Defrost Timer is in the
minimum position. Disconnect the resistor from the Controller Board, and ener-
gize the unit.
After the 1 minute water supply cycle, the defrost cycle starts.
Reconnect a 1.5 k
Ω
- 3.5 k
Ω
resistor to the Connector K3 (pins #1 and #2) after
the first 2 minutes of the defrost cycle.
The unit should start the freeze cycle after 1 minute ± 5 seconds from the resis-
tor connection.
[e] CHECKING THE CONTROLLER BOARD
1) Visually check the sequence with the icemaker operating.
2) Visually check the Controller Board by using the following procedures.
(i) Adjust the Defrost Timer to minimum position.
Disconnect the Thermistor from the Controller Board.
Connect a 1.5 k
Ω
- 3.5 k
Ω
resistor to the Connector K3 (pins #1 and #2), and energize
the unit.
After the 1 minute ± 5 second water supply cycle and the 2 minute ± 10 second defrost
cycle, the unit should start the freeze cycle.
(ii) After the above step (i), disconnect the Float Switch leads from the Controller Board
within the first 5 minutes of the freeze cycle.
The unit should go into the defrost cycle after the first 5 minutes ± 20 seconds of
the freeze cycle.
(iii)
Reconnect the Float Switch Connector to the Controller Board. After the first 5
minutes of the freeze cycle, disconnect the Float Switch leads from the Controller
Board.
At this point, the unit should start the defrost cycle.
MODELS WITH MECHANICAL BIN CONTROL
CAUTION
Dip Switch No. 7 must be set to the ON position. If No. 7 is set to the OFF
position, the machine will run continuously, causing a freeze-up condition.
No adjustment is required. The Bin Control is factory-adjusted.
Содержание KM-900MAH
Страница 1: ...6 59 0 18 668 7 2 2 5 2 2 3 4 5 2 5HOLDELOLW LV D EHDXWLIXO WKLQJ70 5 9 6 180 5 73105...
Страница 10: ...10 5 CONDENSING UNIT URC 12F...
Страница 12: ...12 II GENERAL INFORMATION 1 CONSTRUCTION a KM 900MAH Models with Thermostat Models with Mechanical Bin Control...
Страница 13: ...13 b KM 900MWH Models with Thermostat Models with Mechanical Bin Control...
Страница 14: ...14 c KM 900MRH Models with Thermostat Models with Mechanical Bin Control...
Страница 15: ...15 d KM 900MRH3 Models with Thermostat Models with Mechanical Bin Control...
Страница 30: ...30 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 900MAH...
Страница 31: ...31 b KM 900MWH...
Страница 32: ...32 c KM 900MRH and KM 900MRH3...
Страница 41: ...41 3 TIMING CHART...
Страница 42: ...42...