120
Fig. 32
Sealant
Sealant
Holder
Holder
Holder
Evaporator
Screw
* Leads
* Thermistor
* Thermistor and Leads are FRAGILE.
HANDLE WITH CARE.
15. THERMISTOR FOR CUBE CONTROL
1) Unplug the icemaker or disconnect the power source.
2) Remove the Top Panel, Front Panel and Pipe Cover (Rear).
3) Remove the Connector K4 on the Controller Board, referring to “14. [b] REPLACEMENT.”
4) Unscrew and remove the Thermistor Holder and Thermistor, located on the Evaporator
(Front Side).
5) Install the new thermistor in the reverse order of the removal procedure, by using a sealant
(High-thermal Conduct Type). See Fig. 32.
Note: Recommended sealant is KE4560RTV, manufactured by SINETSU SILICON.
When other type of sealant used, the cube size and performance will be changed.
Do not use silicone sealant as this will insulate the Thermistor.
Содержание IM-100
Страница 5: ...1 I SPECIFICATIONS 1 DIMENSIONS CONNECTIONS a IM 25LE Air cooled ...
Страница 6: ...2 b IM 25CLE Air cooled Until March 2000 production Auxiliary Code K 1 ...
Страница 7: ...3 c IM 21CLE IM 25CLE IM 30CLE Air cooled From April 2000 production Auxiliary Code K 2 ...
Страница 8: ...4 d IM 45LE Air cooled ...
Страница 9: ...5 e IM 45CLE 25 Air cooled ...
Страница 10: ...6 f IM 65LE Air cooled ...
Страница 11: ...7 g IM 100LE IM 130LE IM 130ME Air cooled ...
Страница 12: ...8 h IM 100CLE Air cooled ...
Страница 13: ...9 i IM 160ME Air cooled ...
Страница 14: ...10 j IM 240ME Air cooled ...
Страница 15: ...11 k IM 240M2E Air cooled ...
Страница 16: ...12 l IM 25WLE IM 30WLE Water cooled ...
Страница 17: ...13 m IM 45WLE Water cooled ...
Страница 18: ...14 n IM 65WLE Water cooled ...
Страница 19: ...15 o IM 100WLE IM 130WLE IM 130WME Water cooled ...
Страница 20: ...16 p IM 240WME Water cooled ...
Страница 21: ...17 q IM 240WM2E Water cooled ...
Страница 70: ...66 2 WIRING DIAGRAM a IM 21CLE IM 25LE IM 25CLE IM 30CLE IM 25WLE IM 30WLE ...
Страница 71: ...67 b IM 25L IM 25CL IM 25WL ...
Страница 72: ...68 c IM 45LE IM 45CLE 25 IM 45WLE ...
Страница 73: ...69 d IM 65LE IM 65WLE ...
Страница 74: ...70 e IM 65L IM 65WL ...
Страница 75: ...71 f IM 100LE IM 100CLE IM 100WLE Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Страница 76: ...72 g IM 130LE IM 130WLE Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Страница 77: ...73 h IM 130LE 21 IM 130WLE 21 Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Страница 78: ...74 i IM 130ME IM 130WME Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Страница 79: ...75 j IM 130ME 21 IM 130WME 21 Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Страница 80: ...76 k IM 160ME ...
Страница 81: ...77 l IM 240ME IM 240WME ...
Страница 82: ...78 m IM 240M2E IM 240WM2E ...
Страница 120: ...116 Fig 30 ...
Страница 129: ...HOSHIZAKI EUROPE LTD UNIT A STAFFORD PARK 18 TELFORD SHROPSHIRE TF3 3DJ ENGLAND PHONE 01952 291777 ...