4. OTHERS
PROBLEM CHECK POSSIBLE
CAUSE
REMEDY
1. Out of position.
1. Place in position.
a) Bin Control
Switch
2. Bad contacts.
2. Check for continuity and
replace.
[1] Icemaker will
not stop when
Bin is filled with
ice.
b) Controller Board
1. See “II. 2. CONTROLLER BOARD”.
a) Pump Motor
1. Bearing worn out.
1. Replace.
b) Actuator Motor
1. Gears worn out.
1. Replace.
1. Bearings worn out.
1. Replace.
2. Fan Blade deformed.
2. Replace Fan Blade.
c) Fan Motor
3. Fan Blade does not move
freely.
3. Replace.
d) Compressor
1. Mounting pad out of
position.
1. Reinstall.
[2] Abnormal
noise
e) Refrigerant
Lines
1. Rubbing or touching on
other surfaces.
1. Secure or reset pipes.
[3] Ice in Storage
Bin often melts.
a) Bin Drain
1. Plugged.
1. Clean.
a) Bimetal
Thermostat
1. Defective.
1. Replace.
[4] Fan Motor
does not
change speed
(240ME only).
b) Fan Relay X6
1. Welded contacts or
defective coil.
1. Replace.
96
Содержание IM-100
Страница 5: ...1 I SPECIFICATIONS 1 DIMENSIONS CONNECTIONS a IM 25LE Air cooled ...
Страница 6: ...2 b IM 25CLE Air cooled Until March 2000 production Auxiliary Code K 1 ...
Страница 7: ...3 c IM 21CLE IM 25CLE IM 30CLE Air cooled From April 2000 production Auxiliary Code K 2 ...
Страница 8: ...4 d IM 45LE Air cooled ...
Страница 9: ...5 e IM 45CLE 25 Air cooled ...
Страница 10: ...6 f IM 65LE Air cooled ...
Страница 11: ...7 g IM 100LE IM 130LE IM 130ME Air cooled ...
Страница 12: ...8 h IM 100CLE Air cooled ...
Страница 13: ...9 i IM 160ME Air cooled ...
Страница 14: ...10 j IM 240ME Air cooled ...
Страница 15: ...11 k IM 240M2E Air cooled ...
Страница 16: ...12 l IM 25WLE IM 30WLE Water cooled ...
Страница 17: ...13 m IM 45WLE Water cooled ...
Страница 18: ...14 n IM 65WLE Water cooled ...
Страница 19: ...15 o IM 100WLE IM 130WLE IM 130WME Water cooled ...
Страница 20: ...16 p IM 240WME Water cooled ...
Страница 21: ...17 q IM 240WM2E Water cooled ...
Страница 70: ...66 2 WIRING DIAGRAM a IM 21CLE IM 25LE IM 25CLE IM 30CLE IM 25WLE IM 30WLE ...
Страница 71: ...67 b IM 25L IM 25CL IM 25WL ...
Страница 72: ...68 c IM 45LE IM 45CLE 25 IM 45WLE ...
Страница 73: ...69 d IM 65LE IM 65WLE ...
Страница 74: ...70 e IM 65L IM 65WL ...
Страница 75: ...71 f IM 100LE IM 100CLE IM 100WLE Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Страница 76: ...72 g IM 130LE IM 130WLE Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Страница 77: ...73 h IM 130LE 21 IM 130WLE 21 Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Страница 78: ...74 i IM 130ME IM 130WME Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Страница 79: ...75 j IM 130ME 21 IM 130WME 21 Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Страница 80: ...76 k IM 160ME ...
Страница 81: ...77 l IM 240ME IM 240WME ...
Страница 82: ...78 m IM 240M2E IM 240WM2E ...
Страница 120: ...116 Fig 30 ...
Страница 129: ...HOSHIZAKI EUROPE LTD UNIT A STAFFORD PARK 18 TELFORD SHROPSHIRE TF3 3DJ ENGLAND PHONE 01952 291777 ...